| Finished floor requirement |
|
| Fema map number |
12023C0514C |
| Type Roofing Job |
Replacement - Tear off Existing and Replace |
| Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
Tear off 1–2 layers of existing asphalt shingles from the one-story home. Replace damaged wood decking with OSB/CDX plywood sheathing where applicable, and install two layers of synthetic underlayment featuring Veer Ultra, ice and water shield, and new IKO Dynasty fiberglass shingles finished with a standard ridge. Vent the roof properly and install all accessories, including a drip edge, pipe boots, and flashing. Note that work will not be performed on RF1, RF5, the metal roof on the front porch, or any other sheds or buildings. No structural changes |
| Type of structure |
Mobile Home |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
1782 |
| No. of Stories |
1 |
| Roof Pitch |
2:12 to 4:12 |
| Is the existing roof being removed? |
Yes |
| Type of New Roofing Product |
Asphalt Shingles |
| Florida Product Approval Number |
FL 30310.1 |
| Product Manufacturer |
IKO Industries Ltd |
| Product Description |
IKO Dynasty Fiberglass Shingles |
| Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
| Sealed roof decking options: (Must select an option.) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
| Ventilation: |
Ridge Vent |
| Flashing: |
Use Existing |
| Drip Edge: |
Replace All |
| Valley Treatment: |
New Mineral Surface |
| Second Roof Pitch (if applicable) |
4:12 or Greater |
| Any cable and/or race-way wiring located on or within the roof assembly? |
No |