Permit Details

Permit Search

Permit

Storage Building

5310 SE COUNTRY CLUB RD
LAKE CITY, FL 32025

Permit #
000056304
Application #
76861
Status Completed
  1. Submitted Aug 10, 2026
  2. Issued Aug 11, 2026
  3. Expires May 1, 2027
  4. Completed Nov 2, 2026

Property

Parcel #
08754-003
Owner
Jenkins Charles Lacy Jr, Jenkins Susan Kay
Acres
57.12
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Not yet released
Related permit
—

Job Details

Elevation regulation
Accessory Use
Finished floor requirement
Non-Habitable Structure
Fema map number
12023C0401C
Commercial or Residential?
Residential
Type of Structure
Other
Slab
New
Mechanical
Yes
Electrical
Yes
Plumbing
Yes
Building Length
29
Building Width
16
Total Area (Sqft)
464
Building Height
12
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setback Rear
25'
Septic# (00-0000) or (X00-000)
26-0620
Service Amps
100
Occupancy Use Title
NON-HABITABLE STRUCTURE
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code

Status & Review History

  1. Application pending.
  2. Application Status Update Notification
  3. Application Status Update Notification
  4. Application Status Update Notification
  5. Truss Engineering was not accepted.
  6. Truss Engineering was not accepted.
  7. Proposed Site Plan was not accepted.
  8. Application Status Update Notification
  9. Energy Code Forms was not accepted.
  10. Energy Code Forms was not accepted.
  11. Energy Code Forms was not accepted.
  12. Energy Code Forms was not accepted.
  13. Energy Code Forms was not accepted.
  14. Truss Engineering was not accepted.
  15. Truss Engineering was not accepted.
  16. Application Status Update Notification
  17. Application Status Update Notification
  18. Application Status Update Notification
  19. Application Status Update Notification
  20. Application Status Update Notification
  21. Application Converted
  22. Application Status Update Notification
  23. Application Status Update Notification
  24. Application Status Update Notification
  25. Application Status Update Notification
  26. Application Status Update Notification
  27. Application Status Update Notification
  28. Submitted by building department on applicant's behalf
  29. Application Status Update Notification
  30. Application Status Update Notification
  31. Permit Issued

Contractors

  • Jason Roberts

    Southtrust Construction Llc

    License
    CBC1257119
    Title
    Cert. Building
    Role
    Contractor

    Workers Comp Expired.

  • James Quinn

    Craft Electric Inc

    License
    EC13010994
    Title
    Cert. Electrical
    Role
    Subcontractor
  • Frank L Perkins Iii

    Southern Air Sales And Service Llc

    License
    CAC1816928
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License & Liability Insurance Expired.

  • George M Mc Dilda

    Hogtown Plumbing Inc

    License
    CFC1427052
    Title
    Cert Plumbing
    Role
    Subcontractor

    County License & State License Expired.

  • William P Duffield

    Duffield Home Improvement

    License
    CCC1325785
    Title
    Roofing Contractor
    Role
    Subcontractor

Inspections

  1. Aug 31, 2026

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Christian Allen

  2. Aug 31, 2026

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Christian Allen

  3. Sep 3, 2026

    Passed: Building - Monolithic Slab

    Inspected by Christian Allen

  4. Sep 15, 2026

    Passed: Building - Roof Decking

    Inspected by Gary Pitzer

  5. Sep 15, 2026

    Passed: Building - Wall Sheathing

    Inspected by Gary Pitzer

  6. Sep 17, 2026

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Gary Pitzer

  7. Sep 22, 2026

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Gary Pitzer

  8. Sep 22, 2026

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Gary Pitzer

  9. Sep 22, 2026

    Passed: Electrical - 2nd Rough-In

    Inspected by Gary Pitzer

  10. Sep 22, 2026

    Cancelled: Mechanical - Rough In

    Call In With Insulation Inspection, Split System

    Inspected by Gpitzer

  11. Sep 22, 2026

    Passed: Building - Framing

    Inspected by Gary Pitzer

  12. Sep 23, 2026

    Passed: Mechanical - Rough In

    Split System

    Inspected by Gary Pitzer

  13. Oct 1, 2026

    Passed: Building - Insulation

    Foam Insulation Roof And Walls

    Inspected by Gary Pitzer

  14. Nov 2, 2026

    Passed: Electrical - Permanent Power

    Inspected by Gary Pitzer

  15. Nov 2, 2026

    Passed: Building - Final

    Inspected by Gary Pitzer