Permit Information

Mobile Home Permit

Address 1144 SW KING ST
LAKE CITY, FL 32024
Parcel #: 03282-023
Acres:9.53
Owner:Cinera Group Llc,
Subdivision:
Zoning:A-3
Flood Zone:X
District:5
Application #:77033
Permit #: 000056185
Related Permit:
Submitted:Tuesday, July 21, 2026
Issued:Monday, August 17, 2026
Expires:Wednesday, August 26, 2026
Completed:Wednesday, August 26, 2026
Status: Completed
Septic Release? Yes

Notes

*MMF= BOTTOM OF THE LOWEST BEAM TO BE 1' ABOVE ROAD *INSPECTOR TO VERIFY SERIAL #

Job Details

Elevation regulation Minimum Requirement
Finished floor requirement Bottom of lowest beam must be one foot above the road
Fema map number 12023C0381D
Mobile Home is a: Double Wide
Year Built 2025
Width (Ft.In) 80
Length (Ft.In) 28
Driveway access to home: Existing Drive
Installation Decal # 131091
Septic # 26-0553
Serial # 4896
Wind Zone? 2
Residential or Commercial Use? Residential
Service Amps 200
How many of bedrooms does this home have? 4
How many bathrooms does this home have? 3

Review Notes

7/9/2026 Application pending.
7/9/2026 Application Status Update Notification
7/9/2026 Application Status Update Notification
7/21/2026 Submitted by building department on applicant's behalf
7/21/2026 Application submitted by applicant.
7/28/2026 Permit Issued
7/28/2026 Permit Reissued
7/28/2026 Permit Reissued
8/17/2026 Permit Reissued

Contractors

Name / Business License Title Role
Jose M Hernandez
Eagle Sight Inspections Dba Eagle Sight Inspections Foundations
County License & State License Expired.
IH1149510 Mh Installer (ih) Contractor

Inspections

Inspection Notes Performed By Date
Passed: Engineering - Setbacks Appears To Meet Drawing On File, No Markers Gary Pitzer 8/17/2026
Failed: Mobile Home - Mobile Home Set-Up Final 1, Not Enough Lateral Bracing , 2. Block Supports Spaced To Far Apart, 3. Need Permanent Steps To Egress Doors, 4. Electric No Existing To Septic, 5 Electric At Well Incomplete, 5. Service Panel Need To Completed,( Dead Front Installed , Connectors On Cables, Door Missing, Wiring On Breakers, Ground Electrode Connected To Rods), Septic Release Needed. Gary Pitzer 8/17/2026
Passed: Engineering - Setbacks Gary Pitzer 8/25/2026
Failed: Mobile Home - Mobile Home Set-Up Final Need Permanent Steps At All Egress Doors And Anchored In Place And Septic Inspection Completed Gary Pitzer 8/25/2026
Passed: Mobile Home - Mobile Home Set-Up Final Owner Sent Picture Of Door Not In Use Building Deck At The One Door Location Troy Crews 8/25/2026
Release to power company Troy Crews 8/25/2026
Passed: Engineering - Setbacks Troy Crews 8/25/2026
Release to power company Ewilliams 8/26/2026
Septic Release Inspection Health Dept 8/26/2026

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.