Permit Details

Permit Search

Permit

New Residential Construction

14030 SW TUSTENUGGEE AVE
FORT WHITE, FL 32038

Permit #
000056008
Application #
76568
Status Permit Issued
  1. Submitted Jun 22, 2026
  2. Issued Jun 30, 2026
  3. Expires May 9, 2027
  4. Completed —

Property

Parcel #
09814-008
Owner
Dillon Matthew, Dillon Amber
Acres
20.11
Subdivision
Tustenuggee Acres
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Permit Issued
Septic release
Not yet released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
FFE FOR HOME SHALL BE 12” ABOVE THE ADJACENT GROUND AT ENTIRE PERIMETER
Requirement needed
Slab Inspection
Document needed is
Upload Photos
Document receieved
No
Fema map number
12023C0485C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
2
Heated Area (Sqft)
6164
Total Area (Sqft)
11043
Building Height
22
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
26-0474
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps
400

Status & Review History

  1. Application pending.
  2. Flood Notice to Owner was not accepted.
  3. Application Status Update Notification
  4. Application Status Update Notification
  5. Application Status Update Notification
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Submitted by building department on applicant's behalf
  9. Application Status Update Notification
  10. Application Status Update Notification
  11. Application Status Update Notification
  12. Application Status Update Notification
  13. Permit Issued

Contractors

  • Trever J Townsend

    Townsend Electrical Contractors, Llc

    License
    ER13016105
    Title
    Reg. Electrical
    Role
    Subcontractor
  • James Bertie

    Bertie Heating & Air Conditioning

    License
    CAC058522
    Title
    Class B A/c
    Role
    Subcontractor

    County License & State License Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  1. Jul 22, 2026

    Passed: Electrical - Temporary Power Service

    Inspected by Troy Crews

  2. Jul 24, 2026

    Release to power company

    Inspected by Mgarber

  3. Sep 14, 2026

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Gary Pitzer

  4. Sep 14, 2026

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Gary Pitzer

  5. Oct 8, 2026

    Passed: Engineering - Setbacks

    Inspected by Gary Pitzer

  6. Oct 8, 2026

    Passed: Building - Slab

    Wire And Plastic Taped

    Inspected by Gary Pitzer

  7. Oct 8, 2026

    Passed: Electrical - Footer Steel & Grounding

    Rebar Wired

    Inspected by Gary Pitzer

  8. Oct 8, 2026

    Passed: Building - Footer

    Engineering In File. Ok To Proceed. Ok To Proceed

    Inspected by Gary Pitzer

  9. Nov 10, 2026

    Passed: Building - Wall Sheathing

    Partial Sheathing On The South 1/3 Of House And A 2 Car Garage That Sets Away From Main Part Of Home But Is Attached By Roof Covered Walkway. Ok To Proceed

    Inspected by Gary Pitzer

  10. Nov 10, 2026

    Passed: Building - Ext Strapping/Wall Sheathing

    Partial Strapping Is The South 1/3 Of Home And A Garage That Is With The Main Home the 2 Car Garge That Is Attached To Main House Bu A Covered Wakway Has Not Had An Inspection For Strapping. Ok To Cover

    Inspected by Gary Pitzer

  11. Nov 10, 2026

    Passed: Building - Roof Decking

    Partial Roof Decking On The South 1/3 Of Home And A Separated Garage With Covered Walkway Are Inspected For Decking. Ok To Cover

    Inspected by Gary Pitzer

Documents