Permit Details

Permit Search

Permit

Roof Replacement or Repair

576 SE DEFENDER DR
LAKE CITY, FL 32025

Permit #
000055827
Application #
76537
Status Completed
  1. Submitted May 29, 2026
  2. Issued Jun 4, 2026
  3. Expires Dec 15, 2026
  4. Completed Jun 18, 2026

Property

Parcel #
07140-000
Owner
Little Edward, Little Carolyn
Acres
0.30
Subdivision
Country Club Estates Replat
Zoning
RSF-2
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0311D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Remove existing roofing and properly dispose. Furnish and install ice and water shield where applicable. Furnish and install fiberglass dimensional shingle. Furnish and install all accessories that may include drip edge, pipe boots, and flashing. Erie to remove existing roofing and properly dispose. Erie to furnish and install ice and water shield where applicable. Erie to furnish and install fiberglass dimensional shingle. Erie to furnish and install all accessories that may include drip edge, pipe boots, and flashing. Erie to vent roof properly. Erie to furnish and install Premium Synthetic Underlayment. Erie to prep roof for low-slope application. Erie to furnish and install decking with OSB where applicable. Erie to furnish and install wood fascia Vent roof properly. Furnish and install Premium Synthetic Underlayment. Prep roof for low-slope application. Furnish and install decking with OSB where applicable. Furnish and install wood fascia
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
3096
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL 30310.1
Other Roofing Product Type Not Listed
MOD-BIT/ SA Base + Cap (FL2533.1), Standard Ridge (FL6267.1), 2 Layers Synthetic Veer Ultra (FL20767.1) 
Product Manufacturer
IKO DYNASTY
Product Description
Shingle
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Mineral Surface
Second Roof Pitch (if applicable)
Less than 2:12
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Application Status Update Notification
  5. Application Status Update Notification
  6. Application Status Update Notification
  7. Application submitted by applicant.
  8. Permit Issued

Contractors

  • Robert Rozanski

    Erie Construction Mid-west Llc

    License
    CCC1336152
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Jun 12, 2026

    Passed: Re-Roof - In Progress

    Inspected by Christian Allen

  2. Jun 15, 2026

    Passed: Re-Roof - Roof Affidavit Review

    Inspected by Christian Allen

  3. Jun 17, 2026

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Christian Allen

  4. Jun 18, 2026

    Passed: Re-Roof - Final