| Application #: | 75999 |
| Permit #: |
000055524 |
| Related Permit: |
|
| Submitted: | Tuesday, April 21, 2026 |
| Issued: | Tuesday, April 21, 2026 |
| Expires: | Wednesday, September 23, 2026 |
| Completed: | Wednesday, September 23, 2026 |
| Status: |
Completed |
| Septic Release? |
No |
| Finished floor requirement |
|
| Fema map number |
12023C0505C |
| What is the power service for? |
Existing Mobile Home |
| Other job details: |
EMERGENCY = customer has melted neutral wire feeding directly into the home from meter can causing phase imbalance and partial power.. Like for like replacement of exterior overhead service with disconnect,replace main grounding system, install main surge protection, replace 200 amp underground feeders in conduit to interior sub panel, replace interior sub panel with arc fault/ground fault protection breakers |
| Power Company |
Clay Electric |
| Septic # (00-0000) or (X00-000) |
000 |
| Electrical Code Edition |
2020 National Electrical Code |
| Meter or Account: |
Meter |
| Number of requested AMPS for electrical service: |
200 |
| Is the power service? |
Upgrading Existing Service |
| Residential or Commercial? |
Residential |
| 4/21/2026 |
Application pending. |
| 4/21/2026 |
Submitted by building department on applicant's behalf |
| 4/21/2026 |
Permit Issued |
| Name / Business |
License |
Title |
Role |
Bruce H Fort Jr Mister Sparky
County License & State License & Liability Insurance & Workers Comp Expired. |
EC13008384 |
Cert. Electrical |
Contractor |
| Inspection |
Notes |
Performed By |
Date |
| Cancelled: Electrical - Service Upgrade Final |
|
Mgarber |
4/21/2026 |
| Passed: Electrical - Service Upgrade Final |
New Equipment On Mobile Home Existing Po All New Panel And Wiring |
Troy Crews |
4/21/2026 |
| Release to power company |
|
Troy Crews |
4/21/2026 |
| Cancelled: Electrical - Service Upgrade Final |
Already Done On 4-21-26 |
Tcrews |
6/9/2026 |