Permit Details

Permit Search

Permit

Roof Replacement or Repair

9878 S US HIGHWAY 441
LAKE CITY, FL 32025

Permit #
000055388
Application #
75769
Status Completed
  1. Submitted Mar 31, 2026
  2. Issued Mar 31, 2026
  3. Expires Oct 27, 2026
  4. Completed Apr 30, 2026

Property

Parcel #
09245-005
Owner
Cummings Bryan P, Cummings Belinda D
Acres
27.14
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0415C
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
70
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
FL46717.1
Product Manufacturer
CAPITAL METAL SUPPLY, INC.
Product Description
26 Ga. Steel (min) 1" Nailstrip Roof Panel, 16" Wide or 12"Wide, over 7/16" OSB Sheathing.
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Application Status Update Notification
  4. Permit Issued

Contractors

No contractors are listed on this permit.

Inspections

  1. Apr 14, 2026

    Passed: Re-Roof - In Progress

    Inspected by Christian Allen

  2. Apr 29, 2026

    Passed: Re-Roof - Roof Affidavit Review

    Inspected by Gary Pitzer

  3. Apr 29, 2026

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Gary Pitzer

  4. Apr 30, 2026

    Passed: Re-Roof - Final

    Inspected by Gary Pitzer