Permit Details

Permit Search

Permit

Storage Building

194 SW LYNNWOOD AVE
LAKE CITY, FL 32024

Permit #
000055258
Application #
74996
Status Completed
  1. Submitted Feb 12, 2026
  2. Issued Mar 17, 2026
  3. Expires Nov 4, 2026
  4. Completed May 8, 2026

Property

Parcel #
02818-102
Owner
Crews Dylan A, Crews Jordan H
Acres
0.85
Subdivision
Troy Heights
Zoning
RSF/MH-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Accessory Use
Finished floor requirement
Non-Habitable Structure
Fema map number
12023C0289D
Type of Structure
Storage Building
Commercial or Residential?
Residential
Total Area (Sqft)
750
Septic# (00-0000) or (X00-000)
26-0043
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setback Rear
10' (ACCESSORY)
Building Code Construction Type
III
Building Code Element
B
Building Code Occupancy Types
Storage
Occupancy Use Title
NON-HABITABLE STRUCTURE
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Slab
New
Mechanical
No
Electrical
No
Plumbing
No

Status & Review History

  1. Application pending.
  2. Application Status Update Notification
  3. Application Status Update Notification
  4. Application Status Update Notification
  5. Submitted by building department on applicant's behalf
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Application Status Update Notification
  9. Application Status Update Notification
  10. Application Status Update Notification
  11. Application Status Update Notification
  12. Application Status Update Notification
  13. Permit Issued

Contractors

This is an owner-builder project.

Inspections

  1. Jan 30, 2026

    Septic Release Inspection

    Inspected by Health Dept

  2. Apr 8, 2026

    Passed: Engineering - Setbacks

    Inspected by Gary Pitzer

  3. Apr 8, 2026

    Passed: Building - Monolithic Slab

    2 # 5 Rebar Wired And On Chairs, Plastic And Taped

    Inspected by Gary Pitzer

  4. May 7, 2026

    Failed: Building - Final

    No Access, No Answer At Door

    Inspected by Gary Pitzer

  5. May 8, 2026

    Passed: Building - Final

    Side Set Back Confirmed

    Inspected by Matt Forsyth

Documents