Permit Details

Permit Search

Permit

Roof Replacement or Repair

281 SW WISE DR
LAKE CITY, FL 32024

Permit #
000055077
Application #
75265
Status Completed
  1. Submitted Feb 23, 2026
  2. Issued Feb 23, 2026
  3. Expires Sep 6, 2026
  4. Completed Mar 10, 2026

Property

Parcel #
03113-137
Owner
Tenneboe Tyler J
Acres
0.54
Subdivision
Wise Estates
Zoning
RR
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0381D
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
32
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
10674.1
Product Manufacturer
Owens Corning Asphalt Roofing Shingles and Starters (NON-HVHZ)
Product Description
3-tab, 4-tab, laminated, starter and hip & ridge shingles for use in FBC non-HVHZ jurisdictions.
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Submitted by building department on applicant's behalf
  3. Application Status Update Notification
  4. Application submitted by applicant.
  5. Application submitted by applicant.
  6. Permit Issued

Contractors

  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Contractor

Inspections

  1. Feb 26, 2026

    Passed: Re-Roof - In Progress

    Inspected by Matt Forsyth

  2. Mar 4, 2026

    Passed: Re-Roof - Roof Affidavit Review

    Inspected by Matt Forsyth

  3. Mar 4, 2026

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Matt Forsyth

  4. Mar 6, 2026

    Failed: Re-Roof - In Progress

    Job Not Started Please Reschedule

    Inspected by Matt Forsyth

  5. Mar 10, 2026

    Passed: Re-Roof - Final

    Inspected by Matt Forsyth