Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 9948 SW COUNTY ROAD 240
LAKE CITY, FL 32024
Parcel #: 03644-105
Acres: 4.98
Owner: Leonard George E, Leonard Sylvia M
Subdivision: White Oak Plantation
Zoning: A-3
Flood Zone: X
District: 2
Application #: 74946
Permit #: 000055059
Related Permit:
Submitted: Tuesday, January 27, 2026
Issued: Friday, February 20, 2026
Expires: Friday, March 6, 2026
Completed: Friday, March 6, 2026
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0370C
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Tear off and replace with shingle
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2986
No. of Stories 1
Roof Pitch 2:12 to 4:12
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10124-R35
Product Manufacturer GAF
Product Description Asphalts shingles
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Off-ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
1/27/2026 Application pending.
1/27/2026 Application submitted by applicant.
1/27/2026 Application Status Update Notification
2/9/2026 Application Status Update Notification
2/11/2026 Application Status Update Notification
2/20/2026 Permit Issued
Contractors
Name/ Business License Title Role
Daniel Byrd
Byrds Eye Roofing Inc
CCC1332899 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Matt Forsyth 3/2/2026
Passed: Re-Roof - Roof Affidavit Review Matt Forsyth 3/4/2026
Passed: Re-Roof - Roof Pictures Review Matt Forsyth 3/5/2026
Passed: Re-Roof - Final Matt Forsyth 3/6/2026