Permit Details

Permit Search

Permit

Roof Replacement or Repair

434 SW DEANNA TER
LAKE CITY, FL 32025

Permit #
000054820
Application #
74791
Status Completed
  1. Submitted Jan 13, 2026
  2. Issued Jan 13, 2026
  3. Expires Jul 28, 2026
  4. Completed Jan 29, 2026

Property

Parcel #
08106-232
Owner
Bocanegra Silas,
Acres
0.52
Subdivision
Holly Brook
Zoning
RSF-2
Flood zone
X
District
5

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0294D
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
20
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
FL46717.1
Product Manufacturer
CAPITAL METAL SUPPLY, INC.
Product Description
26 Ga. Steel (min) 1" Nailstrip Roof Panel, 16" Wide or 12"Wide, over 7/16" OSB Sheathing.
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Application Status Update Notification
  5. Permit Issued

Contractors

  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Contractor

Inspections

  1. Jan 14, 2026

    Rescheduled 1/15/2026:Re-Roof - In Progress

    Inspected by Nanderson

  2. Jan 15, 2026

    Passed: Re-Roof - In Progress

    Inspected by Christian Allen

  3. Jan 28, 2026

    Passed: Re-Roof - Roof Affidavit Review

    Inspected by Troy Crews

  4. Jan 28, 2026

    Passed: Re-Roof - Roof Pictures Review

    Inspected by Troy Crews

  5. Jan 29, 2026

    Passed: Re-Roof - Final

    Inspected by Christian Allen