Permit Details

Permit Search

Permit

New Residential Construction

130 SW PLYMOUTH AVE
FORT WHITE, FL 32038

Permit #
000054798
Application #
74234
Status Completed
  1. Submitted Dec 18, 2025
  2. Issued Jan 9, 2026
  3. Expires Nov 4, 2026
  4. Completed May 15, 2026

Property

Parcel #
04021-000
Owner
Cannon Dan Jr
Acres
1.01
Subdivision
—
Zoning
—
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0490C
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1000
Total Area (Sqft)
1135
Building Height
13
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family residence
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0936
If Other, explain the use of the structure.
NA
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application Status Update Notification
  3. Point Review-Corrections Needed
  4. Zoning Approval Documents was not accepted.
  5. Zoning Approval Documents was not accepted.
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Application Status Update Notification
  9. Submitted by building department on applicant's behalf
  10. Application Status Update Notification
  11. Application Status Update Notification
  12. Permit Issued

Contractors

  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Donald R Davis

    High Springs Electric Inc

    License
    CAC1815367
    Title
    Class B A/c
    Role
    Subcontractor
  • Brent Mccall

    Suwannee Valley Plumbing Llc

    License
    CFC1432405
    Title
    Cert. Plumbing
    Role
    Subcontractor
  • Wallace W Powell

    Powell & Sons Roofing,inc.

    License
    CCC057307
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License Expired.

  • William C Herring

    Fla Homes, Inc Reality/ Construction

    License
    CGC052062
    Title
    Cert. General
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Jan 20, 2026

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Christian Allen

  2. Jan 27, 2026

    Passed: Building - Slab

    Inspected by Christian Allen

  3. Feb 9, 2026

    Passed: Building - Wall Sheathing

    Inspected by Christian Allen

  4. Feb 9, 2026

    Passed: Building - Roof Decking

    Inspected by Christian Allen

  5. Feb 9, 2026

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Christian Allen

  6. Feb 10, 2026

    Passed: Building - Framing

    Inspected by Matt Forsyth

  7. Feb 24, 2026

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  8. Feb 24, 2026

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Matt Forsyth

  9. Feb 24, 2026

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  10. Feb 24, 2026

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  11. Feb 25, 2026

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  12. Mar 30, 2026

    Failed: Electrical - Permanent Power

    Need Septic Release

    Inspected by Matt Forsyth

  13. Apr 6, 2026

    Septic Release Inspection

    Inspected by Health Dept

  14. Apr 9, 2026

    Passed: Electrical - Permanent Power

    Inspected by Matt Forsyth

  15. Apr 9, 2026

    Release to power company

    Inspected by Matt Forsyth

  16. May 8, 2026

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents