Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 522 SW RUM ISLAND TER
FORT WHITE, FL 32038
Parcel #: 04336-005
Acres: 5.67
Owner: Fargason William C
Subdivision: Buie's Retreat
Zoning: A-3
Flood Zone: X
District: 2
Application #: 74521
Permit #: 000054675
Related Permit:
Submitted: Friday, December 12, 2025
Issued: Monday, December 15, 2025
Expires: Saturday, June 13, 2026
Completed:
Status: Permit Issued
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0531C
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Remove existing roof, install synthetic underlayment & 26 gauge classic rib metal roofing system
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2300
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Metal
Florida Product Approval Number 14645.6-R5
Other Roofing Product Type Not Listed Underlayment: FL 42148-R4
Product Manufacturer Metal Sales Manufacturing
Product Description 26 gauge Classic Rib
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
12/10/2025 Application pending.
12/10/2025 Application Status Update Notification
12/11/2025 Application Status Update Notification
12/12/2025 Application Status Update Notification
12/12/2025 Submitted by building department on applicant's behalf
12/12/2025 Application Status Update Notification
12/15/2025 Permit Issued
Contractors
Name/ Business License Title Role
Derek L Hickman
Hickman Construction Inc Dba Hickman Metal Roofing
CCC1333609 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date