Permit Details

Permit Search

Permit

New Residential Construction

876 SW WINGATE ST
LAKE CITY, FL 32024

Permit #
000054551
Application #
74323
Status Completed
  1. Submitted Nov 20, 2025
  2. Issued Nov 21, 2025
  3. Expires Apr 25, 2027
  4. Completed Nov 2, 2026

Property

Parcel #
03522-104
Owner
Bishop Michael Phillip, Bishop Shannon Mcrae
Acres
8.21
Subdivision
Columbia Farms
Zoning
A-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0379C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2500
Total Area (Sqft)
4634
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
2023 FLORIDA BUILDING CODE 8TH EDITION AND 2020 NATIONAL ELECTRICAL CODE
Septic# (00-0000) or (X00-000)
25-0576
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.

Status & Review History

  1. Application pending.
  2. Submitted by building department on applicant's behalf
  3. Application Status Update Notification
  4. Application Status Update Notification
  5. Permit Issued

Contractors

This is an owner-builder project.

  • Trever J Townsend

    Townsend Electrical Contractors, Llc

    License
    ER13016105
    Title
    Reg. Electrical
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor
  • Roger Whiddon

    Lake City Plumbing Inc

    License
    CFC1428686
    Title
    Cert Plumbing
    Role
    Subcontractor

Inspections

  1. Dec 16, 2025

    Passed: Private Provider - Private Provider Inspection

    Stem Wall Footer Passed By Mark Thomas

    Inspected by Garber, Melissa

  2. Jan 7, 2026

    Passed: Private Provider - Private Provider Inspection

    Plumbing Rough (underground) Passed By Mark Thomas

    Inspected by Private Provider Inspector

  3. Jan 19, 2026

    Passed: Private Provider - Private Provider Inspection

    Slab/footer Passed By Michael Bishop

    Inspected by Private Provider Inspector

  4. Apr 9, 2026

    Passed: Private Provider - Private Provider Inspection

    Roof Sheathing Passed By Mark Thomas

    Inspected by Private Provider Inspector

  5. Apr 27, 2026

    Passed: Wall Sheathing

    Passed. No Exceptions Taken.

    Inspected by Mark A. Thomas

  6. Apr 30, 2026

    Passed: Mechanical Rough

    Passed: No Exceptions Taken.

    Inspected by Mark A. Thomas

  7. Apr 30, 2026

    Passed: Plumbing Rough (Top-out)

    Passed: No Exceptions Taken.

    Inspected by Mark A. Thomas

  8. May 18, 2026

    Passed: Electrical Rough Inspection

    Passed

    Inspected by Mark A. Thomas

  9. May 18, 2026

    Passed: Framing Inspection

    Passed

    Inspected by Mark A. Thomas

  10. May 20, 2026

    Passed: Windows and Doors

    Passed

    Inspected by Mark A. Thomas

  11. May 20, 2026

    Passed: Insulation

    Passed

    Inspected by Mark A. Thomas

  12. Jul 21, 2026

    Passed: Electrical Pre-Power

    Passed

    Inspected by Mark A. Thomas

  13. Aug 7, 2026

    Septic Release Inspection

    Inspected by Health Dept

  14. Aug 10, 2026

    Release to power company

    Pre-power Release

    Inspected by Ewilliams

  15. Aug 10, 2026

    Passed: Electrical - Temporary Power Service

    Passed Private Provider

    Inspected by Private Provider Inspector

  16. Sep 22, 2026

    Passed: Mechanical Final Inspection

    Passed

    Inspected by Mark A. Thomas

  17. Sep 22, 2026

    Passed: Electrical Final Inspection

    Passed

    Inspected by Mark A. Thomas

  18. Sep 22, 2026

    Passed: Plumbing Final Inspection

    Passed

    Inspected by Mark A. Thomas

  19. Sep 22, 2026

    Passed: Blower Door Test Report

    Passed

    Inspected by Mark A. Thomas

  20. Sep 22, 2026

    Passed: Duct Leakage Test Report

    Passed

    Inspected by Mark A. Thomas

  21. Sep 22, 2026

    Passed: Certificate of Compliance

    Requested

    Inspected by Mark A. Thomas

  22. Oct 27, 2026

    Release to power company

    Inspected by Mgarber

  23. Oct 27, 2026

    Passed: Building - Final

    All Requirements Met To Release Co

    Inspected by Private Provider Inspector

Documents