Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 2151 SW KOONVILLE AVE
LAKE CITY, FL 32024
Parcel #: 00330-000
Acres: 89.80
Owner: Proveaux Stephen Revocable Trust Agreement Executed November 12, 2022
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 73694
Permit #: 000054470
Related Permit:
Submitted: Thursday, October 9, 2025
Issued: Thursday, November 13, 2025
Expires: Sunday, May 17, 2026
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:
*MFE = 12" ABOVE ADJACENT GRADE FOR THE ENTIRE PERIMETER OF THE FOUNDATION PER ENGINEER LETTER, INSPECTOR TO VERIFY *FINAL DRIVE & SEPTIC REQUIRED PRIOR TO RELEASE OF POWER *ASSESSMENTS OWED @ PERM POWER *BLOWER DOOR AND FINAL TERMITE REQUIRED PRIOR TO RELEASE OF CO
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 12" above adjacent grade for the entire perimeter of the foundation
Fema map number 12023C0270C
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2024
Total Area (Sqft) 2815
Building Height 18
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0589
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
10/9/2025 Application pending.
10/9/2025 Point Review - Pre-submittal Review Notes
10/20/2025 Point Review - Pre-submittal Review Notes
10/29/2025 Point Review - Pre-submittal Review Notes
10/29/2025 Point Review - Pre-submittal Review Notes
11/3/2025 Point Review - Pre-submittal Review Notes
11/5/2025 Point Review - Pre-submittal Review Notes
11/5/2025 Point Review - Pre-submittal Review Notes
11/6/2025 New address issued and ticket completed.
11/6/2025 Point Review - Pre-submittal Review Notes
11/7/2025 Point Review - Pre-submittal Review Notes
11/12/2025 Submitted by building department on applicant's behalf
11/12/2025 Point Review - Reviewed
11/12/2025 Zoning Review - Reviewed
11/12/2025 Plan Review - Reviewed
11/12/2025 Final Review - Reviewed
11/12/2025 Application submitted by applicant.
11/12/2025 Final Review - Payment Needed
11/13/2025 Permit Issued
Contractors
Name/ Business License Title Role
Bryan Zecher
Bryan Zecher Homes Inc
CBC1257343 Building Contractor Contractor
Bryan Zecher
Bryan Zecher Homes Inc
CBC1257343 Building Contractor Subcontractor
Bryan Zecher
Bryan Zecher Homes Inc
CBC1257343 Building Contractor Subcontractor
Bryan Zecher
Bryan Zecher Homes Inc
CBC1257343 Building Contractor Subcontractor
Bryan Zecher
Bryan Zecher Homes Inc
CBC1257343 Building Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 10/30/2025
Passed: Building - Footer Matt Forsyth 11/18/2025
Passed: Engineering - Setbacks Matt Forsyth 11/18/2025
Passed: Electrical - Footer Steel & Grounding Matt Forsyth 11/18/2025
Documents
File Name Date File Size
Recorded Notice Of Commencement 20251114 142811.pdf 2025.11.14 727.52kB
Inspections Checklist.pdf 2025.11.13 319.00kB
Original Permit 20251113.pdf 2025.11.13 136.86kB
Application 73694 Bnz Payment Receipt 2025-11-13.pdf 2025.11.13 39.99kB
Columbia County Fl - New Residential Construction Invoice-73694.pdf 2025.11.12 158.96kB
Columbia County Fl - New Residential Construction Invoice-73694.pdf 2025.11.12 158.96kB
Application.pdf 2025.11.12 194.33kB
Engineer Letter Providing Minimum Floor Elevation Requirements.pdf 2025.11.12 1.71MB
Proveaux Site Plan.pdf 2025.11.06 203.52kB
Signed Proposed Site Plan.pdf 2025.11.06 178.69kB
2151 Sw Koonville Ave.pdf 2025.11.06 341.50kB
Approved Site Plan 73694.pdf 2025.11.06 329.17kB
Proveaux Eh 25-0589.pdf 2025.11.05 816.43kB
Subcontractor Form 20251021 163558.pdf 2025.10.30 120.53kB
Residential Checklist 20251020 100557.pdf 2025.10.30 1.28MB
Approved Structural # 73694.pdf 2025.10.29 2.83MB
Approved Truss Plans # 73694.pdf 2025.10.29 2.23MB
Energy Code Forms 20251015 135336.pdf 2025.10.17 139.86kB
Manual J Forms 20251015 135336.pdf 2025.10.17 86.45kB
Architectural Plans 20251015 135336.pdf 2025.10.15 1.59MB
Floodplain Notice To Owner 20251013 130024.pdf 2025.10.14 108.30kB
Product Approval Code Specifications Form 20251013 133029.pdf 2025.10.14 202.88kB
Owner And Contractor Signature Page 20251013 130024.pdf 2025.10.14 401.16kB
Truss Engineering 20251014 113704.pdf 2025.10.14 2.11MB
Structural Engineering And Wind Load Calculations 20251014 113704.pdf 2025.10.14 2.83MB
Recorded Deed 20251009 154134.pdf 2025.10.09 91.69kB
Property Appraiser Parcel Details Printed Page 20251009 154134.pdf 2025.10.09 1.04MB