Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 539 NW RIDGE GLN
WELLBORN, FL 32094
Parcel #: 00176-002
Acres: 15.59
Owner: Smith James D, Edstrom-smith Laura
Subdivision:
Zoning: A-3
Flood Zone: X
District: 3
Application #: 73358
Permit #: 000054338
Related Permit:
Submitted: Friday, September 19, 2025
Issued: Tuesday, October 28, 2025
Expires: Thursday, November 6, 2025
Completed: Thursday, November 6, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0260C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 6500
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL 18355-R8
Product Manufacturer TAMKO
Product Description TITAN SHINGLES
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
9/19/2025 Application pending.
10/28/2025 Permit Issued
Contractors
Name/ Business License Title Role
Paula E Kennedy
Gainesville Roofing & Co Inc
Workers Comp Expired.
CCC1328678 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Spray Foam Attic No Need For Roof Ventilation Matt Forsyth 11/4/2025
Passed: Re-Roof - Roof Pictures Review Matt Forsyth 11/4/2025
Passed: Re-Roof - Final Matt Forsyth 11/6/2025
Passed: Re-Roof - Roof Affidavit Review Matt Forsyth 11/6/2025