Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 420 SW PHILLIPS CIR
LAKE CITY, FL 32024
Parcel #: 02739-244
Acres: 0.51
Owner: Caldwell Hammond Donald Jr, Caldwell Muriel M
Subdivision: Turkey Run
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 73765
Permit #: 000054285
Related Permit:
Submitted: Wednesday, October 15, 2025
Issued: Monday, October 20, 2025
Expires: Saturday, April 18, 2026
Completed:
Status: Final Review - Complete
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0290D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) house -Tear off existing shingles to plywood and replace with GAF Timberline Architectural Shingles
Type of structure Storage or Garage Building
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 800
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL.10124.R31
Product Manufacturer GAF
Product Description Architectural shingle
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
10/15/2025 Application pending.
10/15/2025 Application submitted by applicant.
10/15/2025 City of Lake City Utilities Notified.
10/15/2025 Point Review - Processing
10/20/2025 Point Review - Processing
10/20/2025 Final Review - Payment Needed
10/20/2025 Permit Issued
10/20/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Kevin L Bedenbaugh Jr
Plumb Level Construction Co Llc
CCC1329482 Roofing Contractor Contractor
Inspections
Inspection Notes Performed By Date