Permit Details

Permit Search

Permit

New Residential Construction

736 SW ROCK WAY
FORT WHITE, FL 32038

Permit #
000054162
Application #
72996
Status Completed
  1. Submitted Sep 2, 2025
  2. Issued Sep 29, 2025
  3. Expires Oct 10, 2026
  4. Completed Apr 16, 2026

Property

Parcel #
09931-007
Owner
Burk Corey A, Burk Lindsey R
Acres
2.03
Subdivision
—
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0495C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1890
Total Area (Sqft)
2776
Building Height
21
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0502
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Pre-submittal Review Notes
  3. Point Review - Pre-submittal Review Notes
  4. Point Review - Ready for applicant submittal
  5. Application submitted by applicant.
  6. Point Review - Reviewed
  7. Zoning Review - Reviewed
  8. Plan Review - Sent to plan review
  9. Plan Review - Building Approved
  10. Plan Review - Electrical Approved
  11. Plan Review - Mechanical Approved
  12. Plan Review - Plumbing Approved
  13. Plan Review - Fuel/Gas Approved
  14. Plan Review - Reviewed
  15. Final Review - Sent for final review
  16. Final Review - Reviewed
  17. Final Review - Payment Needed
  18. Permit Issued
  19. Final Review - Complete
  20. Permit Status Update Notification

Contractors

  • Matthew L Hartley

    Hartley Brothers, Inc.

    License
    CGC1520103
    Title
    Cert. General
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Robert M Bounds

    Bounds Heating & Air Inc

    License
    CAC057642
    Title
    Class A A/c
    Role
    Subcontractor

Inspections

  1. Sep 2, 2025

    Cancelled: Engineering - As-Built Survey Review

    Inspected by Melissa Garber

  2. Oct 13, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Need Picture Of Supply Pressure

    Inspected by Anthony Aslan

  3. Oct 21, 2025

    Passed: Engineering - Setbacks

    Appears Within Setbacks

    Inspected by Aslan, Anthony W.

  4. Oct 21, 2025

    Passed: Building - Monolithic Slab

    Inspected by Anthony Aslan

  5. Oct 22, 2025

    Passed: Building - Monolithic Slab

    Already Done On 10-21

    Inspected by Troy Crews

  6. Oct 22, 2025

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  7. Oct 24, 2025

    Passed: Electrical - Temporary Power Service

    Inspected 10-21-2025

    Inspected by Anthony Aslan

  8. Nov 5, 2025

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  9. Nov 5, 2025

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  10. Nov 7, 2025

    Release to power company

    Passed Temp Pwr Inspection

    Inspected by Ewilliams

  11. Nov 10, 2025

    Passed: Building - Window Attachment

    Inspected by Troy Crews

  12. Nov 10, 2025

    Passed: Building - Window Attachment

    Inspected by Troy Crews

  13. Dec 3, 2025

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  14. Dec 3, 2025

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  15. Dec 3, 2025

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  16. Dec 3, 2025

    Passed: Building - Framing

    Inspected by Troy Crews

  17. Dec 15, 2025

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Christian Allen

  18. Dec 15, 2025

    Passed: Building - Insulation

    Inspected by Christian Allen

  19. Feb 6, 2026

    Septic Release Inspection

    Inspected by Health Dept

  20. Feb 17, 2026

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  21. Feb 17, 2026

    Release to power company

    Inspected by Troy Crews

  22. Apr 10, 2026

    Passed: Building - Final

    Need Blower Door Test And Termite Final For Release Also Please Send Video Clip Of Smoke Detectors I Could Not Activate

    Inspected by Troy Crews

  23. Apr 13, 2026

    Passed: Building - Final

    Blower Door And Termite Received, Smoke Detectors Recorded By Owner Per Superintendent

    Inspected by Troy Crews

Documents