Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 569 SW BELLFLOWER DR
LAKE CITY, FL 32024
Parcel #: 02731-037
Acres: 0.42
Owner: Adams Homes Of Northwest Florida, Inc,
Subdivision: Preserve At Laurel Lake Unit 1
Zoning: PRD
Flood Zone: X
District: 3
Application #: 72787
Permit #: 000054160
Related Permit:
Submitted: Tuesday, August 19, 2025
Issued: Monday, September 29, 2025
Expires: Monday, September 7, 2026
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:
*MFE = 107' PER SUBDIVISION PLAT, SURVEYOR CONFIRMATION REQUIRED FOR FFE & SETBACKS *ASSESSMENTS OWED @ PERM POWER *FINAL DRIVE PRIOR TO RELEASE OF POWER *CITY TAP INSPECTION REQUIRED PRIOR TO FINAL-- REQUEST THROUGH COUNTY *BLOWER DOOR AND FINAL TERMITE REQUIRED PRIOR TO CO
LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City's Utility Directors approved a tap application for water and sewer services.
Job Details
Finished floor requirement
Fema map number 12023C0513C
What is the power service for? Existing Site Built Home
Power Company Clay Electric
Electrical Code Edition 2017 National Electrical Code
Meter or Account: Meter
Meter or Account #: 156 217 765
Number of requested AMPS for electrical service: 200
Is the power service? Generator Install
Residential or Commercial? Residential
Review Notes
8/19/2025 Application pending.
8/19/2025 City of Lake City Utilities Notified.
9/3/2025 Point Review - Pre-submittal Review Notes
9/12/2025 Point Review - Ready for applicant submittal
9/15/2025 Point Review - Ready for applicant submittal
9/17/2025 Point Review - Ready for applicant submittal
9/17/2025 Application submitted by applicant.
9/17/2025 City of Lake City Utilities Notified.
9/17/2025 Point Review - Reviewed
9/17/2025 Zoning Review - Reviewed
9/17/2025 Plan Review - Sent to plan review
9/17/2025 Plan Review - Building Approved
9/17/2025 Plan Review - Electrical Approved
9/17/2025 Plan Review - Mechanical Approved
9/17/2025 Plan Review - Plumbing Approved
9/17/2025 Plan Review - Fuel/Gas Approved
9/17/2025 Plan Review - Reviewed
9/17/2025 Final Review - Sent for final review
9/17/2025 Final Review - Reviewed
9/17/2025 Final Review - Payment Needed
9/29/2025 Permit Issued
Contractors
Name/ Business License Title Role
William Adams
Adams Homes Of Northwest Florida Inc
Liability Insurance Expired.
CRC1330146 Cert. Residential Contractor
Joseph H Strada Jr
Strada Services Inc Dba Strada Electric & Security
EC13003715 Cert Electrical Subcontractor
Joseph H Strada Jr
Strada Services Inc
CAC043953 Cert. A/c Class “b” Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 2/4/2026
Rescheduled 2/9/2026:Building - Monolithic Slab Tcrews 2/6/2026
Rescheduled 2/9/2026:Electrical - Footer Steel & Grounding Tcrews 2/6/2026
Rescheduled 2/9/2026:Engineering - Setbacks Tcrews 2/6/2026
Passed: Building - Monolithic Slab Troy Crews 2/9/2026
Passed: Electrical - Footer Steel & Grounding Need Ground Wire Installed Prior To Pour Troy Crews 2/9/2026
Passed: Engineering - Setbacks Setbacks To Be Confirmed By Surveyor Troy Crews 2/9/2026
Passed: Building - Roof Decking Troy Crews 2/18/2026
Passed: Building - Wall Sheathing Troy Crews 2/18/2026
Cancelled: Building - Ext Strapping/Wall Sheathing Already Done Tcrews 3/5/2026
Failed: Building - Framing Windows Not Complete With All Screws Troy Crews 3/5/2026
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 3/5/2026
Passed: Plumbing/Gas - Tub Set/Shower Pan Troy Crews 3/5/2026
Passed: Mechanical - Rough In Troy Crews 3/5/2026
Passed: Electrical - 2nd Rough-In Troy Crews 3/5/2026
Passed: Building - Framing Window Screws Have Been Completed Troy Crews 3/6/2026
Passed: Building - Insulation Batts On Walls And Partial Ceiling Gary Pitzer 3/11/2026
Documents