Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Mobile Home Permit

Address 129 NW GENELL LOOP
LAKE CITY, FL 32055
Parcel #: 02058-010
Acres: 1.19
Owner: Pfs Solutions Inc,
Subdivision: Parnell Hills Unit Ii
Zoning: A-3
Flood Zone: X
District: 1
Application #: 72174
Permit #: 000054134
Related Permit:
Submitted: Sunday, July 20, 2025
Issued: Wednesday, September 24, 2025
Expires: Sunday, April 5, 2026
Completed:
Status: Final Review - Complete
Septic Release? Yes
Notes:
*SEPTIC FINAL MUST BE REC'D PRIOR TO RELEASE OF POWER *INSPECTOR TO CONFIRM 30' FRONT (ROADS) SETBACKS *REPLACING EXISTING MH, OLD MH MUST BE REMOVED PRIOR TO CO
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement Bottom of lowest floor joist must be one foot above the road
Fema map number 12023C0280D
Mobile Home is a: Double Wide
Year Built 2025
Width (Ft.In) 28
Length (Ft.In) 56
Driveway access to home: Existing Drive
Installation Decal # 121273
Septic # (00-0000) or (X00-000) 25-0551
Setbacks Front 30'
Setback Side 1 30' (2ND FRONT)
Setbacks Rear 25'
Setback Side 2 25'
Are you applying for a 5 year temporary permit? No
Serial # FL261-000-H-B205270AB
Wind Zone? 2
Residential or Commercial Use? Residential
Service Amps 202
How many of bedrooms does this home have? 3
How many bathrooms does this home have? 2
Review Notes
7/20/2025 Application pending.
7/21/2025 Point Review - Pre-submittal Review Notes NEEDED * SERIAL # * FLOODPLAIN NOTICE TO OWNER * BLOCKING DIAGRAM COMPLETED ON COUNTY FORM * row app - verify existing drive
7/30/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER *DRIVE APPROVAL-- SEE APP #72185 *site plan updated to reflect 30' minimum setback from front property lines (roads)
7/31/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
8/6/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
8/15/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
8/26/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
8/28/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/1/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/5/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/9/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/10/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/11/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/14/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/15/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/17/2025 Point Review - Pre-submittal Review Notes NEEDED: *SERIAL # *FLOODPLAIN NOTICE TO OWNER-- MUST BE DIGITAL SIGNATURE OR WET SIGNATURE-- FONTS NOT ACCEPTED *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/21/2025 Point Review - Pre-submittal Review Notes NEEDED: *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/22/2025 Point Review - Pre-submittal Review Notes NEEDED: *SITE PLAN UPDATED TO REFLECT 30' MINIMUM SETBACK FROM FRONT PROPERTY LINES (ROADS)
9/23/2025 Point Review - Ready for applicant submittal *PLEASE LOG IN TO YOUR PORTAL AND SUBMIT APPLICATION- THIS APPLICATION WILL NOT BEGIN REVIEW UNTIL IT HAS BEEN SUBMITTED.
9/23/2025 Application submitted by applicant.
9/24/2025 Point Review - Reviewed
9/24/2025 Zoning Review - Reviewed
9/24/2025 Plan Review - Reviewed
9/24/2025 Final Review - Reviewed
9/24/2025 Permit Issued Permit #000054134 created and approved.
9/24/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Michael Earnest
Infinity Renovators Llc
County License & State License Expired.
IH1121539 Mh Installer (ih) Contractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Michael A Boland
Ace A/c Of Ocala Llc
CAC1817716 Cert Class B A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 7/30/2025
Failed: Mobile Home - Mobile Home Set-Up Final Need Permanent Steps In Place, Remove Skiting For Inspection, Doors Locked Gary Pitzer 10/2/2025
Passed: Mobile Home - Mobile Home Set-Up Final Per Correction Photos Gary Pitzer 10/7/2025
Release to power company Gary Pitzer 10/7/2025