Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Mobile Home Permit

Address 1174 SW GRAPE ST
LAKE CITY, FL 32024
Parcel #: 03744-203
Acres: 10.64
Owner: Brown William Othel,
Subdivision: Pine Hills Unr
Zoning: ESA-2
Flood Zone: X
District: 2
Application #: 72966
Permit #: 000054075
Related Permit:
Submitted: Friday, August 29, 2025
Issued: Wednesday, September 17, 2025
Expires: Monday, March 16, 2026
Completed:
Status: Final Review - Complete
Septic Release? No
Notes:
*MFE = 32" ABOVE THE ADJACENT GROUND FOR ENTIRE PERIMETER OF THE FOUNDATION *FINAL SEPTIC REQUIRED PRIOR TO RELEASE OF POWER AND CO
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 32" above adjacent ground for entire perimeter
Fema map number 12023C0390C
Mobile Home is a: Double Wide
Year Built 2025
Width (Ft.In) 28
Length (Ft.In) 72
Driveway access to home: Existing Drive
Installation Decal # 119733
Septic # (00-0000) or (X00-000) 25-0702
Setbacks Front 30'
Setback Side 1 25'
Setbacks Rear 25'
Setback Side 2 25'
Are you applying for a 5 year temporary permit? No
Serial # SOU020326ALABAC
Wind Zone? 2
Residential or Commercial Use? Residential
Service Amps 200
How many of bedrooms does this home have? 4
How many bathrooms does this home have? 3
Review Notes
8/29/2025 Application pending.
9/2/2025 Point Review - Pre-submittal Review Notes NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED DEVELOPMENT. AN ENGINEER LETTER WILL BE REQUIRED TO ASSURE THAT THE MINIMUM FLOOR ELEVATION WILL BE SUFFICIENT TO AVOID POSSIBLE RISING WATERS OF THE AREA.
9/5/2025 Point Review - Pre-submittal Review Notes NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED DEVELOPMENT. AN ENGINEER LETTER WILL BE REQUIRED TO ASSURE THAT THE MINIMUM FLOOR ELEVATION WILL BE SUFFICIENT TO AVOID POSSIBLE RISING WATERS OF THE AREA.
9/12/2025 Point Review - Pre-submittal Review Notes NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *THERE IS A SIGNIFICANT DIFFERENCE IN THE ELEVATION OF THE ROAD AND THE ELEVATION AT THE PROPOSED DEVELOPMENT. AN ENGINEER LETTER WILL BE REQUIRED TO ASSURE THAT THE MINIMUM FLOOR ELEVATION WILL BE SUFFICIENT TO AVOID POSSIBLE RISING WATERS OF THE AREA.
9/17/2025 Application submitted by applicant.
9/17/2025 Point Review - Reviewed
9/17/2025 Zoning Review - Reviewed
9/17/2025 Plan Review - Reviewed
9/17/2025 Final Review - Reviewed
9/17/2025 Final Review - Payment Needed
9/17/2025 Permit Issued Permit #000054075 created and approved.
9/17/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Dale Houston
Dale Houstons Mobile Home Set Up And Service
IH1133271 Mh Installer (ih) Contractor
Glenn Whittington
Whittington Electric Inc
EC13002957 Electrical Contractor Subcontractor
Steven M Mollman
Mollman Air Conditioning And Refrigeration Llc
CAC1819696 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date