Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 288 SW CABOOSE DR
FORT WHITE, FL 32038
Parcel #: 04059-123
Acres: 0.51
Owner: Terry Craig A, Terry Lisa G
Subdivision: Fort White Station
Zoning:
Flood Zone: X
District: 2
Application #: 69962
Permit #: 000054064
Related Permit:
Submitted: Friday, July 25, 2025
Issued: Tuesday, September 16, 2025
Expires: Monday, June 15, 2026
Completed:
Status: Final Review - Complete
Septic Release? Yes
Notes:
*MFE = BOTTOM OF LOWEST BEAM MUST BE 1' ABOVE THE ROAD *FINAL SEPTIC REQUIRED PRIOR TO RELEASE OF POWER *ASSESSMENTS OWED @ PERM POWER, BLOWER DOOR AND FINAL TERMITE REQUIRED PRIOR TO CO
Job Details
Finished floor requirement
Fema map number 12023C0187D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Remove double layer of shingle, install new metal roof
Type of structure Storage or Garage Building
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 16
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Metal
Florida Product Approval Number FL # 17992.1 R4
Product Manufacturer CAPITAL METAL SUPPLY, INC.
Product Description Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16” OSB
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Review Notes
3/17/2025 Application pending.
7/29/2025 Point Review - Pre-submittal Review Notes
8/28/2025 Point Review - Pre-submittal Review Notes
9/2/2025 Point Review - Pre-submittal Review Notes
9/5/2025 Point Review - Pre-submittal Review Notes
9/11/2025 Point Review - Pre-submittal Review Notes
9/14/2025 Point Review - Ready for applicant submittal
9/15/2025 Point Review - Ready for applicant submittal
9/15/2025 Application submitted by applicant.
9/15/2025 Point Review - Reviewed
9/15/2025 Zoning Review - Reviewed
9/15/2025 Plan Review - Sent to plan review
9/16/2025 Plan Review - Plumbing Approved
9/16/2025 Plan Review - Mechanical Approved
9/16/2025 Plan Review - Electrical Approved
9/16/2025 Plan Review - Building Approved
9/16/2025 Plan Review - Reviewed
9/16/2025 Final Review - Sent for final review
9/16/2025 Final Review - Reviewed
9/16/2025 Final Review - Payment Needed
9/16/2025 Permit Issued
9/16/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Jeffrey P Bokor
Dwc Contracting Llc
Workers Comp Expired.
CGC1517145 General Contractor Contractor
James Butler Jr
Butler Plumbing Of Gainesville Inc
Workers Comp Expired.
CFC057960 Plumbing Contractor Subcontractor
Jeffrey Bokor
Dwc Contracting Llc
Workers Comp Expired.
CCC1329756 Roofing Contractor Subcontractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Samuel L Roberts
Air Ducks Inc
Liability Insurance Expired.
CAC1817288 Class "b" A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Power Service Anthony Aslan 9/17/2025
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 9/22/2025
Cancelled: Building - Footer Aaslan 9/24/2025
Passed: Building - Monolithic Slab Christian Allen 9/25/2025
Passed: Engineering - Setbacks Dwelling Appears To Be Within Set Back Christian Allen 9/25/2025
Release to power company Temp Pwr Ewilliams 9/29/2025
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 10/16/2025
Passed: Building - Roof Decking Anthony Aslan 10/16/2025
Passed: Electrical - 2nd Rough-In Anthony Aslan 10/16/2025
Passed: Building - Framing Christian Allen 10/27/2025
Passed: Plumbing/Gas - 2nd Rough-In Christian Allen 10/27/2025
Passed: Plumbing/Gas - Tub Set/Shower Pan Christian Allen 10/27/2025
Passed: Mechanical - Rough In Install Nail Plate For Dyer Exhaust Vent Stack On Top Plate ... Will Check At Next Inspection 10/27/2025
Passed: Building - Insulation Christian Allen 10/29/2025
Passed: Electrical - Permanent Power Septic Needed Matt Forsyth 12/17/2025
Release to power company Septic Rec'd Ewilliams 1/9/2026
Septic Release Inspection Health Dept 1/9/2026