Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 1274 SE COUNTY ROAD 349
LAKE CITY, FL 32025
Parcel #: 09398-003
Acres: 9.90
Owner: Witt Dylan L, Witt Courtney T
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 71971
Permit #: 000053998
Related Permit:
Submitted: Tuesday, July 8, 2025
Issued: Monday, September 8, 2025
Expires: Sunday, August 9, 2026
Completed:
Status: Final Review - Complete
Septic Release? No
Notes:
*LEGAL LOT BY WAY OF 1 TIME SPLIT *MFE = 12" ABOVE THE HIGHEST ADJACENT GRADE AND DRAIN AWAY FROM THE FOUNDATION, SURVEYOR CONFIRMATION REQUIRED THAT THE FFE MEETS OR EXCEEDS THE STATED REQUIREMENTS *FINAL SEPTIC REQUIRED PRIOR TO RELEASE OF POWER *ASSESSMENTS OWED @ PERM POWER, BLOWER DOOR AND TERMITE FINAL REQUIRED PRIOR TO CO
Job Details
Finished floor requirement
Fema map number 12023C0270C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 46.39
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL-39780
Product Manufacturer GAF
Product Description Asphalt Shingles
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Off-ridge Vent
Flashing: Repair Existing
Drip Edge: Repair Existing
Valley Treatment: Use Existing
Review Notes
7/8/2025 Application pending.
7/29/2025 Point Review - Pre-submittal Review Notes
8/5/2025 Point Review - Pre-submittal Review Notes
8/13/2025 Point Review - Pre-submittal Review Notes
8/14/2025 Point Review - Ready for applicant submittal
8/14/2025 Application submitted by applicant.
8/14/2025 Point Review - Reviewed
8/14/2025 Zoning Review - Reviewed
8/15/2025 Plan Review - Plumbing Approved
8/15/2025 Plan Review - Mechanical Approved
8/15/2025 Plan Review - Electrical Approved
8/15/2025 Plan Review - Building Approved
8/15/2025 Plan Review - Reviewed
8/15/2025 Final Review - Payment Needed
8/22/2025 Final Review - Payment Needed
8/26/2025 Final Review - Payment Needed
8/29/2025 Final Review - Payment Needed
9/5/2025 Final Review - Payment Needed
9/8/2025 Permit Issued
9/19/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Caleb J Wentworth
Wentworth Construction Services, Llc
CBC1266933 Cert. Building Contractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Timothy D Shatto
Shatto Heating & Air, Inc.
CAC057875 A/c Class B Subcontractor
Ronald D Cochran
Cochran Plumbing Services Llc
Liability Insurance Expired.
CFC1429154 Plumbing Contractor Subcontractor
Caleb J Wentworth
Wentworth Construction Services, Llc
CCC1334975 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Need To Post Address At Road, Footer With 2#5 Rebar On Chairs,electric Bond On Rebar Gary Pitzer 9/17/2025
Passed: Plumbing/Gas - 1st Underground Rough–In Christian Allen 10/6/2025
Passed: Building - Slab Christian Allen 10/20/2025
Passed: Building - Roof Decking Christian Allen 11/24/2025
Passed: Building - Wall Sheathing Christian Allen 11/24/2025
Failed: Building - Framing All Post Shall Be Nailed With Long Nails Per Simpson Specs, Also Several Points Though Out Building Need Greater Up Lift Protection, Brackets That Exist Need 2 1/2 Inch Nails Please Have These Ready At Time Of Mep Inspections Gary Pitzer 12/10/2025
Passed: Building - Spot Check Windows Secured Only, No Doors Gary Pitzer 12/11/2025
Passed: Building - Framing Troy Crews 1/29/2026
Passed: Electrical - 2nd Rough-In Troy Crews 1/29/2026
Passed: Mechanical - Rough In Troy Crews 1/29/2026
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 1/29/2026
Passed: Building - Insulation Troy Crews 2/10/2026