Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 218 SE ANASTASIA ST
LAKE CITY, FL 32025
Parcel #: 08360-164
Acres: 0.43
Owner: Smith Kermit A, Smith Rita A
Subdivision: Eastwood Unit 1
Zoning: RSF-2
Flood Zone: X
District: 5
Application #: 72971
Permit #: 000053955
Related Permit:
Submitted: Friday, August 29, 2025
Issued: Monday, September 1, 2025
Expires: Tuesday, September 9, 2025
Completed: Tuesday, September 9, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0313D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replace plywood decking as needed
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2736
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number 18355.1
Product Manufacturer TAMKO Building Products LLC
Product Description Titan XT Shingles
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Review Notes
8/29/2025 Application pending.
8/29/2025 Application submitted by applicant.
8/29/2025 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_WATER,.
8/29/2025 Final Review - Complete
8/31/2025 Failed to auto issue permit on credit card payment. Cannot issue permit until this application's inspections have been approved.
9/1/2025 Permit Issued Permit #000053955 created and approved.
Contractors
Name/ Business License Title Role
Tanesha Bouthner
Solar Roofing & Construction Specialist Corp
CCC1335469 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - Roof Affidavit Review Troy Crews 8/29/2025
Passed: Re-Roof - In Progress Anthony Aslan 9/5/2025
Passed: Re-Roof - Roof Pictures Review Received Anthony Aslan 9/8/2025
Passed: Re-Roof - Final Anthony Aslan 9/9/2025