Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Storage Building Permit

Address 202 SE MORNING GLORY CT
LAKE CITY, FL 32025
Parcel #: 07571-008
Acres: 4.91
Owner: Schuck Davin S,
Subdivision:
Zoning: RSF/MH-2
Flood Zone: X
District: 4
Application #: 72423
Permit #: 000053924
Related Permit:
Submitted: Tuesday, July 29, 2025
Issued: Tuesday, August 26, 2025
Expires: Sunday, February 22, 2026
Completed:
Status: Final Review - Complete
Septic Release? Yes
Notes:
*NON-HABITABLE STRUCTURE *NEW SLAB, NO MEP
LAKE CITY UTLITY CUSTOMER SERVICE NOTES Locates must be obtained to ensure that the existing utility infrastructure is not damaged or obstructed.
Job Details
Elevation regulation Accessory Use
Finished floor requirement Non-Habitable Structure
Fema map number 12023C0311D
Type of Structure Storage Building
Commercial or Residential? Residential
Total Area (Sqft) 1500
Septic# (00-0000) or (X00-000) 25-0128
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setback Rear 10' (accessory)
Building Code Construction Type III
Building Code Element B
Building Code Occupancy Types Storage
Occupancy Use Title non-habitable structure
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Building Height 12'
Length 62'
Width 30'
Slab New
Mechanical No
Electrical No
Plumbing No
Review Notes
7/29/2025 Application pending.
7/31/2025 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER,.
7/31/2025 Point Review - Pre-submittal Review Notes staff to verify seal needed... *enviromental health approval. please call 386-758-1058 *owner disclosure statement *recorded noc prior to any inspections *product approval codes for any extirior prducts. ex-- (doors, windows)
8/3/2025 Point Review - Pre-submittal Review Notes NEEDED: *ENVIROMENTAL HEALTH APPROVAL-- PLEASE CALL 386-758-1058 *OWNER DISCLOSURE STATEMENT *site plan with dimensions from each property line to the proposed location of the storage building *PRODUCT APPROVAL CODES FOR ANY EXTIRIOR PRDUCTS. EX-- (DOORS, WINDOWS) *ORIGINAL PLANS OR DIGITALLY SEALED PLANS ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/18/2025 Point Review - Pre-submittal Review Notes NEEDED: *ENVIROMENTAL HEALTH APPROVAL-- PLEASE CALL 386-758-1058 *ORIGINAL PLANS OR DIGITALLY SEALED PLANS *proposed site plan with dimensions from each property line to location of building-- uploaded site plan only references mobile home ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/19/2025 Point Review - Pre-submittal Review Notes NEEDED: *ENVIROMENTAL HEALTH APPROVAL-- PLEASE CALL 386-758-1058 *PROPOSED SITE PLAN WITH DIMENSIONS FROM EACH PROPERTY LINE TO LOCATION OF BUILDING-- UPLOADED SITE PLAN ONLY REFERENCES MOBILE HOME ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/21/2025 Point Review - Pre-submittal Review Notes NEEDED: *ENVIROMENTAL HEALTH APPROVAL-- pending signature, should have soon ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/21/2025 Point Review - Ready for applicant submittal NEEDED: * PLEASE LOG IN TO YOUR PORTAL AND SUBMIT APPLICATION- THIS APPLICATION WILL NOT MOVE FORWARD UNTIL IT HAS BEEN SUBMITTED ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/21/2025 Application submitted by applicant.
8/21/2025 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER,.
8/21/2025 Point Review - Reviewed ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/21/2025 Zoning Review - Reviewed ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/22/2025 Plan Review - Building Approved ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/22/2025 Plan Review - Reviewed ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/26/2025 Final Review - Reviewed ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/26/2025 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED NOC
8/26/2025 Permit Issued Permit #000053924 created and approved.
8/27/2025 Final Review - Complete ***PRIOR TO INSPECTIONS*** RECORDED NOC
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 8/25/2025