Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 351 SW LIGHTWOOD PL
FORT WHITE, FL 32038
Parcel #: 04313-007
Acres: 4.00
Owner: Allison James Michael, Allison Christy L
Subdivision: Rum Island Woods
Zoning: A-3
Flood Zone: X
District: 2
Application #: 72287
Permit #: 000053656
Related Permit:
Submitted: Thursday, July 24, 2025
Issued: Friday, July 25, 2025
Expires: Wednesday, August 13, 2025
Completed: Wednesday, August 13, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0531C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 4400
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL5444-R25
Other Roofing Product Type Not Listed 12sq Modified Bitumen | Certainteed | FL2533-R33
Product Manufacturer Certainteed
Product Description Laminated Asphalt shingles
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Second Roof Pitch (if applicable) Less than 2:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
7/24/2025 Application pending.
7/24/2025 Application submitted by applicant.
7/25/2025 Final Review - Payment Needed
7/25/2025 Permit Issued
7/25/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Daniel Dufresne
Covenant Roofing & Construction Inc
CCC1332763 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Tear Off, Drying Anthony Aslan 8/6/2025
Passed: Re-Roof - Roof Affidavit Review Anthony Aslan 8/11/2025
Failed: Re-Roof - Roof Pictures Review No Venting Photos Anthony Aslan 8/11/2025
Cancelled: Re-Roof - Roof Pictures Review Neonta Anderson 8/12/2025
Passed: Re-Roof - Roof Pictures Review We Are Looking For Attic Venting Not Waste Stack Venting. Anthony Aslan 8/13/2025
Rescheduled 8/13/2025:Re-Roof - Final Troy Crews 8/13/2025
Passed: Re-Roof - Final Anthony Aslan 8/13/2025