Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 3050 SE COUNTY ROAD 18
LAKE CITY, FL 32025
Parcel #: 10631-000
Acres: 21.97
Owner: American Telephone & Telegraph (signer Eli Morgan, At&t Senior Pm)
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 70353
Permit #: 000053646
Related Permit:
Submitted: Tuesday, May 13, 2025
Issued: Wednesday, July 23, 2025
Expires: Monday, January 19, 2026
Completed:
Status: Final Review - Complete
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0508C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure Commercial Building
Commercial or Residential Commercial
Roof Area (for this job) Sq Ft 7718
No. of Stories 1
Roof Pitch Less than 2:12
Is the existing roof being removed? Yes
Type of New Roofing Product Build-Up or Modified
Florida Product Approval Number FL17013-R24 (non-HVHZ)
Product Manufacturer Johns Manville
Product Description APP;BUR;SBS Asphalt Applied, SBS Heat Welded;SBS Cod Applied;EPDM;PVC;TPO;Registration - JM Insulation Only
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Second Roof Pitch (if applicable) Less than 2:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
4/11/2025 Application pending.
5/13/2025 Application submitted by applicant.
5/13/2025 Final Review - Corrections Needed
5/18/2025 Final Review - Corrections Needed
5/29/2025 Final Review - Corrections Needed
6/16/2025 Final Review - Corrections Needed
6/21/2025 Final Review - Corrections Needed
6/24/2025 Final Review - Corrections Needed
6/24/2025 Final Review - Corrections Needed
6/25/2025 Final Review - Corrections Needed
6/27/2025 Final Review - Corrections Needed
7/2/2025 Final Review - Corrections Needed
7/3/2025 Final Review - Corrections Needed
7/4/2025 Final Review - Corrections Needed
7/7/2025 Final Review - Corrections Needed
7/8/2025 Final Review - Corrections Needed
7/13/2025 Final Review - Payment Needed
7/14/2025 Final Review - Payment Needed
7/15/2025 Final Review - Payment Needed
7/17/2025 Final Review - Payment Needed
7/23/2025 Permit Issued
7/24/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Gary L Register
Register Roofing & Sheet Metal, Inc.
CCC1331028 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date