Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Mobile Home Permit

Address 493 SW MEMORIAL DR
FORT WHITE, FL 32038
Parcel #: 04149-519
Acres: 1.45
Owner: Norris Stephen C
Subdivision: Wilson Springs Community Phase 1-a
Zoning: A-3
Flood Zone: AE
District: 2
Application #: 70539
Permit #: 000053629
Related Permit: Site Use Approval: SITE-USE2025-170
Submitted: Monday, April 28, 2025
Issued: Monday, July 21, 2025
Expires: Saturday, January 17, 2026
Completed:
Status: Permit Issued
Septic Release? No
Notes:
* A FINAL ELEVATION CERTIFICATE PRIOR TO PERMINANT POWER AND THE CO. *ELECTRIC SHALL BE WATERPROOFED TO DFE. *MECHANICAL SHALL ALSO BE ELEVATED ABOVE THE DFE.
Job Details
Finished floor requirement
Fema map number 12023C0293D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 48
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL5444-R22
Product Manufacturer CertainTeed Asphalt Shingles (HVHZ)
Product Description Laminated asphalt roof shingles for use in FBC HVHZ jurisdictions
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
5/13/2025 Point Review - Reviewed
5/15/2025 Zoning Review - Corrections Needed
5/16/2025 Zoning Review - Corrections Needed
5/27/2025 Zoning Review - Corrections Needed
5/27/2025 Plan Review - Reviewed
5/27/2025 Zoning Review - Corrections Needed
5/29/2025 Zoning Review - Corrections Needed
6/10/2025 Zoning Review - Corrections Needed
6/16/2025 Zoning Review - Corrections Needed
6/21/2025 Zoning Review - Corrections Needed
6/27/2025 Zoning Review - Corrections Needed
7/3/2025 Zoning Review - Documents Required
7/18/2025 Zoning Review - Documents Required
7/21/2025 Zoning Review - Reviewed
7/21/2025 Permit Issued
Contractors
Name/ Business License Title Role
Dale Houston
Dale Houstons Mobile Home Set Up And Service
IH1133271 Mh Installer (ih) Contractor
Inspections
Inspection Notes Performed By Date
Passed: Mobile Home - In County Pre-Mobile Home before set-up Mobile Home Is In Good Condition But Has Personal Belongings Throughout The House Need Windzone Decal For Permitting Matt Forsyth 5/6/2025
Documents
File Name Date File Size