Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 459 SW WINTHROP PL
FORT WHITE, FL 32038
Parcel #: 03832-247
Acres: 5.71
Owner: Refaelov Reuven
Subdivision: Spring Run Unr Phase 1
Zoning: A-3
Flood Zone: X
District: 2
Application #: 72163
Permit #: 000053621
Related Permit:
Submitted: Friday, July 18, 2025
Issued: Friday, July 18, 2025
Expires: Tuesday, July 29, 2025
Completed: Tuesday, July 29, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0480C
Type Roofing Job Overlay with Metal
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 40
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Metal over shingle
Type of New Roofing Product Metal
Florida Product Approval Number 17992.1 R4
Product Manufacturer CAPITAL METAL SUPPLY, INC.
Product Description Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16” OSB
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
7/18/2025 Application pending.
7/18/2025 Application submitted by applicant.
7/18/2025 Final Review - Payment Needed
7/18/2025 Permit Issued Permit #000053621 created and approved.
7/18/2025 Failed to auto issue permit on credit card payment. Illegal characters in path.
7/21/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Request Pictures In Affidavit For Final Inspection Matt Forsyth 7/22/2025
Passed: Re-Roof - Final Matt Forsyth 7/29/2025