Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Additions Permit

Address 588 SW MEADOW TER
LAKE CITY, FL 32024
Parcel #: 03405-113
Acres: 1.27
Owner: Shaheen David, Shaheen Christy
Subdivision: Southwood Meadows
Zoning: A-3
Flood Zone: X
District: 5
Application #: 71565
Permit #: 000053537
Related Permit: Site Use Approval: SITE-USE2025-099
Submitted: Wednesday, June 18, 2025
Issued: Tuesday, July 8, 2025
Expires: Sunday, January 4, 2026
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:
*FINAL SEPTIC REQUIRED PRIOR TO RELEASE OF POWER
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement Meet existing structure
Fema map number 12023C0383D
Description of addition: Addition of Bedroom and Bathroom Add of 533SQFT
Select driveway access to property: Existing Drive
Fire sprinklers? No
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setback Rear 25'
Heated Area (Sqft) 533
Total Area (Sqft) 533
Total Estimated Cost 150000.00
Dev Permit # F023-
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0444
Is this an addition for commercial or residential use? Residential
Sealed roof decking options. (Must select one.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
6/16/2025 Application pending.
6/18/2025 Point Review - Pre-submittal Review Notes NEEDED: *COMPLETE CONTRACTOR SECTION, CONSTRUCTION DETAILS, ROOF OPTIONS, APPLICANT INFORMATION, AND UPLOAD RELATIVE DOCUMENTS FOR US TO REVIEW *OWNERS PHONE NUMBER
6/21/2025 Point Review - Pre-submittal Review Notes NEEDED: *COMPLETE CONTRACTOR SECTION, CONSTRUCTION DETAILS, ROOF OPTIONS, APPLICANT INFORMATION, AND UPLOAD RELATIVE DOCUMENTS FOR US TO REVIEW *OWNERS PHONE NUMBER
6/24/2025 Point Review - Pre-submittal Review Notes NEEDED: *COMPLETE CONTRACTOR SECTION, CONSTRUCTION DETAILS, ROOF OPTIONS, APPLICANT INFORMATION, AND UPLOAD RELATIVE DOCUMENTS FOR US TO REVIEW *OWNERS PHONE NUMBER
6/26/2025 Point Review - Ready for applicant submittal NEEDED: *PLEASE LOG IN TO YOUR PORTAL AND SUBMIT APPLICATION- THIS APPLICATION WILL NOT BEGIN REVIEW UNTIL IT HAS BEEN SUBMITTED *PLAN REVIEWER TO DETERMINE IF ENERGY CODE & MANUAL J REQUIRED *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
6/27/2025 Point Review - Ready for applicant submittal NEEDED: *PLEASE LOG IN TO YOUR PORTAL AND SUBMIT APPLICATION- THIS APPLICATION WILL NOT BEGIN REVIEW UNTIL IT HAS BEEN SUBMITTED *PLAN REVIEWER TO DETERMINE IF ENERGY CODE & MANUAL J REQUIRED *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
6/29/2025 Point Review - Ready for applicant submittal NEEDED: *PLEASE LOG IN TO YOUR PORTAL AND SUBMIT APPLICATION- THIS APPLICATION WILL NOT BEGIN REVIEW UNTIL IT HAS BEEN SUBMITTED *PLAN REVIEWER TO DETERMINE IF ENERGY CODE & MANUAL J REQUIRED *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
6/30/2025 Application submitted by applicant.
6/30/2025 Point Review - Received-Hard Copy Application NEEDED: *PLAN REVIEWER TO DETERMINE IF ENERGY CODE & MANUAL J REQUIRED *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
6/30/2025 Point Review - Reviewed NEEDED: *PLAN REVIEWER TO DETERMINE IF ENERGY CODE & MANUAL J REQUIRED *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
6/30/2025 Zoning Review - Reviewed NEEDED: *PLAN REVIEWER TO DETERMINE IF ENERGY CODE & MANUAL J REQUIRED *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
7/1/2025 Plan Review - Documents Required NEEDED: ENERGY CODE & MANUAL J REQUIRED *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
7/7/2025 Plan Review - Plumbing Approved NEEDED: *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
7/7/2025 Plan Review - Mechanical Approved NEEDED: *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
7/7/2025 Plan Review - Electrical Approved NEEDED: *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
7/7/2025 Plan Review - Building Approved NEEDED: *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
7/7/2025 Plan Review - Reviewed NEEDED: *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
7/7/2025 Final Review - Processing NEEDED: *PLAN REVIEWER TO DETERMINE IF ANY FURTHER DOCUMENTS NEEDED
7/7/2025 Final Review - Reviewed
7/7/2025 Final Review - Payment Needed
7/8/2025 Final Review - Complete
7/8/2025 Permit Issued Permit #000053537 created and approved.
Contractors
Name/ Business License Title Role
Roger Leavitt
Roger Leavitt Electric
EC13006243 Cert. Electrical Subcontractor
Jeremiah J Cook
Cook's Heat & Air Conditioning Inc
CAC1813212 Class B A/c Contractor Subcontractor
Kenneth R Roche
Ken Roche Plumbing Inc Dba Plumbing Now
CFC1426527 Plumbing Contractor Subcontractor
Ralph W Laverdure
Rwl Roofing Llc
CCC1328590 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 6/26/2025
(Requested) Building-Footer
(Requested) Engineering-Setbacks