Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 265 SW CADENCE GLN
LAKE CITY, FL 32024
Parcel #: 03001-110
Acres: 0.99
Owner: Maronda Homes Llc Of Florida
Subdivision: Forest Cove
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 71366
Permit #: 000053327
Related Permit: Site Use Approval: SITE-USE2025-031
Submitted: Wednesday, June 4, 2025
Issued: Thursday, June 5, 2025
Expires: Sunday, February 8, 2026
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:
*MFE = 101.4' PER SUBDIVISION PLAT, SURVEYOR TO CONFIRM FFE, ELEVATION CONFIRMATION REC'D @ 102.8' *AS BUILT SURVEY PRIOR TO CO PER PLAT FOR DRAINAGE SWALES AND LOT CONTOURS *SEPTIC FINAL AND FINAL DRIVE REQUIRED PRIOR TO RELEASE OF POWER *BLOWER DOOR AND FINAL TERMITE REQUIRED PRIOR TO CO
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 101.4'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0289D
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 2286
Total Area (Sqft) 3520
Building Height 24
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title SINGLE FAMILY DWELLING
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0123
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
6/2/2025 Application pending.
6/2/2025 Point Review - Pre-submittal Review Notes NEEDED * ARCHITECT/ENGINEER NAME AND ADDRESS CELL TO BE FILLED IN * PLEASE DO NOT UPLOAD DOCUMENTS UNDER THE APPROVED SITE PLAN FILE THIS IS FOR OFFICE USE ONLY
6/4/2025 Point Review - Ready for applicant submittal
6/4/2025 Application submitted by applicant.
6/4/2025 Point Review - Printed-Online Application
6/4/2025 Zoning Review - Reviewed
6/5/2025 Plan Review - Building Approved
6/5/2025 Plan Review - Electrical Approved
6/5/2025 Plan Review - Mechanical Approved
6/5/2025 Plan Review - Plumbing Approved
6/5/2025 Plan Review - Fuel/Gas Approved
6/5/2025 Plan Review - Reviewed
6/5/2025 Final Review - Reviewed
6/5/2025 Final Review - Payment Needed
6/5/2025 Permit Issued Permit #000053327 created and approved.
Contractors
Name/ Business License Title Role
Adam Gaslin
Maronda Homes Llc Of Florida
CRC1331630 Cert. Residential Contractor
Paul K Coleman
Colemans Plumbing Inc.
CFC1425624 Certified Plumbing Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Ryan Hinote
Nature Coast Electrical
EC13011934 Cert. Electrical Subcontractor
Robert M Bounds
Bounds Heating & Air Inc
CAC057642 Class A A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Waste Pipe Installed Water Supply Also Installed Under Pressure Matt Forsyth 6/16/2025
Passed: Electrical - Temporary Service Matt Forsyth 6/17/2025
Release to power company Matt Forsyth 6/17/2025
Rescheduled 6/20/2025:Building - Monolithic Slab Matt Forsyth 6/18/2025
Rescheduled 6/20/2025:Engineering - Setbacks Matt Forsyth 6/18/2025
Passed: Building - Monolithic Slab Matt Forsyth 6/20/2025
Passed: Engineering - Setbacks Matt Forsyth 6/20/2025
Cancelled: Engineering - Setbacks Matt Forsyth 6/20/2025
Cancelled: Building - Monolithic Slab Matt Forsyth 6/20/2025
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 6/26/2025
Passed: Building - Roof Decking Matt Forsyth 6/26/2025
Passed: Building - Strapping Matt Forsyth 6/26/2025
Passed: Building - Wall Sheathing Matt Forsyth 6/26/2025
Passed: Building - Ext Strapping/Wall Sheathing Windows And Doors Installed Matt Forsyth 7/8/2025
Cancelled: Building - Wall Sheathing Matt Forsyth 7/8/2025
Passed: Electrical - 2nd Rough-In Exhaust Fan Feeder Matt Forsyth 7/15/2025
Passed: Mechanical - Rough In Matt Forsyth 7/15/2025
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 7/15/2025
Cancelled: Plumbing/Gas - Tub Set/Shower Pan Matt Forsyth 7/15/2025
Passed: Building - Framing Matt Forsyth 7/17/2025
Passed: Building - Insulation Matt Forsyth 7/17/2025
Cancelled: Building - Framing Matt Forsyth 7/17/2025
Cancelled: Building - Insulation Matt Forsyth 7/17/2025
Septic Release Inspection Health Dept 8/6/2025
Passed: Electrical - Permanent Power All Requirements Met To Release Power-- 8.13.25 Mg Matt Forsyth 8/12/2025
Release to power company Mgarber 8/13/2025
(Requested) Building-Framing
(Requested) Building-Insulation
Documents
File Name Date File Size