Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Electrical Service Permit

Address 3234 SW CARPENTER RD
LAKE CITY, FL 32024
Parcel #: 00455-000
Acres: 309.78
Owner: Sauls Perry R, Sauls Betty T
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 71086
Permit #: 000053322
Related Permit: Site Use Approval: SITE-USE2025-032
Submitted: Tuesday, May 20, 2025
Issued: Thursday, June 5, 2025
Expires: Tuesday, December 2, 2025
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0513C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 4200
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number fl18355
Product Manufacturer tamko
Product Description heritage/laminated shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Review Notes
5/20/2025 Application pending.
5/20/2025 Application submitted by applicant.
6/4/2025 Final Review - Payment Needed
6/4/2025 Final Review - Complete
6/5/2025 Permit Issued
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 6/9/2025
Documents
File Name Date File Size