Permit Details

Permit Search

Permit

Solar Power System

355 SW HUNTER LEIGH PL
LAKE CITY, FL 32024

Permit #
000053272
Application #
70602
Status Completed
  1. Submitted Apr 30, 2025
  2. Issued Jun 5, 2025
  3. Expires Dec 20, 2025
  4. Completed Jun 23, 2025

Property

Parcel #
09607-201
Owner
Hayes Donald J,
Acres
17.28
Subdivision
Melissa's Secret Gardens Unr
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0395C
PV Type
Stand Alone PV System with Batteries- (DC system) separate electric permit not required.
Grounding
N.E.C. Chapter 690
AC Options
Exposed
AC Options (Cont..)
In Conduit
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Power Company
Clay Electric
Residential or Commercial?
Residential
Setbacks Front
30'
Setback Side 1
25'
Setbacks Side 2
25'
Setbacks Rear
25'
Where are the panels mounted?
Ground Mounted
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Point Review - Reviewed
  5. Zoning Review - Documents Required
  6. Plan Review - Electrical Approved
  7. Plan Review - Building Approved
  8. Zoning Review - Documents Required
  9. Zoning Review - Documents Required
  10. Zoning Review - Reviewed
  11. Final Review - Documents Required
  12. Plan Review - Reviewed
  13. Final Review - Reviewed
  14. Final Review - Payment Needed
  15. Permit Issued
  16. Final Review - Complete
  17. Permit Reissued

Contractors

  • Edward J Dempsey

    Enlight Energy Llc

    License
    EC13012151
    Title
    Cert. Electrical
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Jun 4, 2025

    Failed: Solar - Solar Final

    Need Placards For Both Units Served, Red Background, White Letters. ( Fire Department Disconnect ) Plus Address On Each Unit On Placard

    Inspected by Gary Pitzer

  2. Jun 23, 2025

    Passed: Solar - Solar Final

    Inspected by Gary Pitzer

  3. Jun 23, 2025

    Release to power company

    Inspected by Gary Pitzer