Permit Details

Permit Search

Permit

New Residential Construction

1075 SW MARYNIK DR
HIGH SPRINGS, FL 32643

Permit #
000053152
Application #
70522
Status Completed
  1. Submitted Apr 25, 2025
  2. Issued May 19, 2025
  3. Expires Jun 7, 2026
  4. Completed Dec 11, 2025

Property

Parcel #
10006-234
Owner
Bousquet Wayne P Ii, Bousquet Veronica
Acres
5.16
Subdivision
River Rise Residential Unit 2
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0513C
This is the construction of a
Single Family Dwelling
Setback Side 1
30'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2017
Total Area (Sqft)
3022
Building Height
24
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0365
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Plan Review - Plumbing Approved
  4. Plan Review - Mechanical Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Building Approved
  7. Plan Review - Reviewed
  8. Point Review - Processing
  9. Point Review - Reviewed
  10. Zoning Review - Processing
  11. Zoning Review - Processing
  12. Final Review - Processing
  13. Final Review - Processing
  14. Zoning Review - Reviewed
  15. Final Review - Reviewed
  16. Final Review - Payment Needed
  17. Permit Issued
  18. Final Review - Complete
  19. Permit Status Update Notification

Contractors

  • Stuart L Amira

    Amira Builders, Inc.

    License
    CRC1327171
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License Expired.

  • James Butler Jr

    Butler Plumbing Of Gainesville Inc

    License
    CFC057960
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Robert M Bounds

    Bounds Heating & Air Inc

    License
    CAC057642
    Title
    Class A A/c
    Role
    Subcontractor

Inspections

  1. Jun 11, 2025

    Passed: Building - Footer

    Inspected by Anthony Aslan

  2. Jun 11, 2025

    Passed: Engineering - Setbacks

    Appears Within Setbacks

    Inspected by Anthony Aslan

  3. Jun 23, 2025

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  4. Jun 23, 2025

    Release to power company

    Inspected by Anthony Aslan

  5. Jun 27, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  6. Jul 3, 2025

    Passed: Building - Slab

    Inspected by Anthony Aslan

  7. Jul 3, 2025

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Anthony Aslan

  8. Jul 28, 2025

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  9. Jul 28, 2025

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  10. Aug 13, 2025

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  11. Aug 13, 2025

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  12. Aug 13, 2025

    Cancelled: Building - Strapping

    Inspected by Anthony Aslan

  13. Aug 13, 2025

    Passed: Building - Framing

    Truss In Front Room To Left Of Entry

    Inspected by Anthony Aslan

  14. Aug 13, 2025

    Passed: Plumbing/Gas - 2nd Rough-In

    Venting Tee In Attic Wrong Direction

    Inspected by Anthony Aslan

  15. Aug 22, 2025

    Passed: Building - Insulation

    Walls R-13 Cellulose, Vault And Knee Wall R-30

    Inspected by Anthony Aslan

  16. Oct 1, 2025

    Passed: Electrical - Permanent Power

    Need Septic Release

    Inspected by Anthony Aslan

  17. Oct 10, 2025

    Release to power company

    Rec'd Septic

    Inspected by Ewilliams

  18. Oct 10, 2025

    Septic Release Inspection

    Inspected by Health Dept

  19. Dec 9, 2025

    Passed: Building - Final

    Termite Final Required Prior To Release Of Co-- 12.9.25 Mg

    Inspected by Christian Allen

Documents