Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 149 SW BELLFLOWER DR
LAKE CITY, FL 32024
Parcel #: 02731-013
Acres: 0.38
Owner: Adams Homes Of Northwest Florida Inc,
Subdivision: Preserve At Laurel Lake Unit 1
Zoning: PRD
Flood Zone: X
District: 3
Application #: 70374
Permit #: 000053078
Related Permit:
Submitted: Tuesday, April 15, 2025
Issued: Sunday, June 22, 2025
Expires: Friday, December 19, 2025
Completed:
Status: Permit Reissued
Septic Release? Yes
Notes:
*MFE = 114.75' ENGINEER LETTER, SURVEYOR TO CONFIRM FFE AND SETBACKS *DRIVE FINAL REQUIRED PRIOR TO POWER RELEASE *CITY TAP INSPECTION REQUIRED PRIOR TO FINAL-- REQUEST THROUGH COUNTY
LAKE CITY UTLITY CUSTOMER SERVICE NOTES 04/30/25 The Utility Department approved the tap application for water and sewer services for this location. Locates must be obtained to ensure that the existing utility infrastructure is not damaged or obstructed.
Job Details
Finished floor requirement
Fema map number 12023C0311D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replace wood as needed.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 23.33
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Metal
Florida Product Approval Number FL17992.1R2
Product Manufacturer Capital
Product Description 26 GA Rib
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
4/14/2025 Application pending.
4/15/2025 Application submitted by applicant.
4/15/2025 City of Lake City Utilities Notified.
4/15/2025 Point Review - Processing
4/17/2025 Point Review - Printed-Online Application
4/29/2025 Plan Review - Plumbing Approved
4/29/2025 Plan Review - Mechanical Approved
4/29/2025 Plan Review - Electrical Approved
4/29/2025 Plan Review - Building Approved
4/29/2025 Plan Review - Reviewed
4/29/2025 Zoning Review - Processing
4/29/2025 Zoning Review - Reviewed
4/29/2025 Final Review - Corrections Needed
4/30/2025 Final Review - Reviewed
4/30/2025 Final Review - Payment Needed
5/9/2025 Final Review - Payment Needed
5/12/2025 Permit Issued
6/22/2025 Permit Reissued
Contractors
Name/ Business License Title Role
William Adams
Adams Homes Of Northwest Florida Inc
CRC1330146 Cert. Residential Contractor
Shawn Reynolds
Ncf Electrical Services Llc
Liability Insurance Expired.
EC13011927 Cert. Electrical Subcontractor
Derrick L Williams
D L Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 5/7/2025
Documents