Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 149 SW BELLFLOWER DR
LAKE CITY, FL 32024
Parcel #: 02731-013
Acres: 0.38
Owner: Adams Homes Of Northwest Florida Inc,
Subdivision: Preserve At Laurel Lake Unit 1
Zoning: PRD
Flood Zone: X
District: 3
Application #: 70374
Permit #: 000053078
Related Permit:
Submitted: Tuesday, April 15, 2025
Issued: Sunday, June 22, 2025
Expires: Friday, December 19, 2025
Completed:
Status: Permit Reissued
Septic Release? Yes
Notes:
*MFE = 114.75' ENGINEER LETTER, SURVEYOR TO CONFIRM FFE AND SETBACKS *DRIVE FINAL REQUIRED PRIOR TO POWER RELEASE *CITY TAP INSPECTION REQUIRED PRIOR TO FINAL-- REQUEST THROUGH COUNTY
LAKE CITY UTLITY CUSTOMER SERVICE NOTES 04/30/25 The Utility Department approved the tap application for water and sewer services for this location. Locates must be obtained to ensure that the existing utility infrastructure is not damaged or obstructed.
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 114.75'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved No
Fema map number 12023C0290D
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 2166
Total Area (Sqft) 2943
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0289
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
4/14/2025 Application pending.
4/15/2025 Application submitted by applicant.
4/15/2025 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
4/15/2025 Point Review - Processing NEED * SEPTIC APPROVAL PAPERWORK OR CITY OF LAKE CITY ACCESSIBILITY LETTER FYI * DO NOT PUT ANYTHING IN THE APPROVED SITE PLANS - THAT IS FOR US TO UPLOAD INTO.
4/17/2025 Point Review - Printed-Online Application NEED * SEPTIC APPROVAL PAPERWORK OR CITY OF LAKE CITY ACCESSIBILITY LETTER - CITY UTILITIES LETTER UPLOADED FYI * DO NOT PUT ANYTHING IN THE APPROVED SITE PLANS - THAT IS FOR US TO UPLOAD INTO.
4/29/2025 Plan Review - Plumbing Approved NEED CITY UTILITIES LETTER UPLOADED FYI * DO NOT PUT ANYTHING IN THE APPROVED SITE PLANS - THAT IS FOR US TO UPLOAD INTO.
4/29/2025 Plan Review - Mechanical Approved NEED CITY UTILITIES LETTER UPLOADED FYI * DO NOT PUT ANYTHING IN THE APPROVED SITE PLANS - THAT IS FOR US TO UPLOAD INTO.
4/29/2025 Plan Review - Electrical Approved NEED CITY UTILITIES LETTER UPLOADED FYI * DO NOT PUT ANYTHING IN THE APPROVED SITE PLANS - THAT IS FOR US TO UPLOAD INTO.
4/29/2025 Plan Review - Building Approved NEED CITY UTILITIES LETTER UPLOADED FYI * DO NOT PUT ANYTHING IN THE APPROVED SITE PLANS - THAT IS FOR US TO UPLOAD INTO.
4/29/2025 Plan Review - Reviewed NEED CITY UTILITIES LETTER UPLOADED FYI * DO NOT PUT ANYTHING IN THE APPROVED SITE PLANS - THAT IS FOR US TO UPLOAD INTO.
4/29/2025 Zoning Review - Processing NEED CITY UTILITIES LETTER UPLOADED FYI * DO NOT PUT ANYTHING IN THE APPROVED SITE PLANS - THAT IS FOR US TO UPLOAD INTO.
4/29/2025 Zoning Review - Reviewed NEEDED: *DRIVE APPROVAL-- PENDING INSPECTION, SEE APP #70217
4/29/2025 Final Review - Corrections Needed NEEDED: *DRIVE APPROVAL-- PENDING INSPECTION, SEE APP #70217
4/30/2025 Final Review - Reviewed
4/30/2025 Final Review - Payment Needed
5/9/2025 Final Review - Payment Needed
5/12/2025 Permit Issued Permit #000053078 created and approved.
6/22/2025 Permit Reissued Permit reissued to reflect updated information.
Contractors
Name/ Business License Title Role
William Adams
Adams Homes Of Northwest Florida Inc
CRC1330146 Cert. Residential Contractor
Shawn Reynolds
Ncf Electrical Services Llc
Liability Insurance Expired.
EC13011927 Cert. Electrical Subcontractor
Derrick L Williams
D L Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 5/7/2025
Documents
File Name Date File Size
Subcontractor Form 20250806 101632.pdf 2025.08.06 350.08kB
Updated Permit 20250622.pdf 2025.07.05 32.86kB
Approved Site Plan 70374.pdf 2025.07.05 80.20kB
Original Permit 20250512.pdf 2025.06.23 32.83kB
City Of Lake City Accessibility Letter.pdf 2025.06.22 145.87kB
Detail By Entity Name 2025-04-15 09.46.39.632.pdf 2025.06.22 152.82kB
Proposed Site Plan 20250415 084739.pdf 2025.06.22 156.92kB
Truss Order Summary.pdf 2025.06.22 163.41kB
911 Address Form 20250415 092831v1.pdf 2025.06.21 217.47kB
Manual J Forms 20250415 092216v1.pdf 2025.06.21 1.04MB
Subcontractor Form 20250415 092217v1.jpg 2025.06.20 119.36kB
Architectural Plans 20250415 092212v1.pdf 2025.06.19 8.63MB
Approved Plans 70374 2025-04-29 07.49.10.377.pdf 2025.06.19 8.63MB
Preserve_at_laurel_lake_ut1 (to Be Deleted).pdf 2025.04.29 5.94MB
Preserve_at_laurel_lake_ut1 Lot 13.pdf 2025.04.29 5.93MB
Approved Truss Plans 70374 2025-04-29 07.46.35.925.pdf 2025.04.29 906.76kB
City Or County Utility Availability Letter 20250416 083716v1.pdf 2025.04.16 36.67kB
Recorded Notice Of Commencement 20250415 094009v1.pdf 2025.04.15 66.00kB
Residential Checklist 20250415 094009v1.pdf 2025.04.15 449.41kB
Contractor Letter Of Authorization 20250415 092831v1.pdf 2025.04.15 57.45kB
Product Approval Code Specifications Form 20250415 092542v1.pdf 2025.04.15 32.00kB
Floodplain Notice To Owner 20250415 092541v1.pdf 2025.04.15 105.60kB
Energy Code Forms 20250415 092541v1.pdf 2025.04.15 637.45kB
Truss Engineering 20250415 092218v1.pdf 2025.04.15 895.15kB
Structural Engineering And Wind Load Calculations (to Be Deleted).pdf 2025.04.15 895.15kB
Property Appraiser Parcel Details Printed Page 20250415 084739.pdf 2025.04.15 190.25kB
Owner And Contractor Signature Page 20250415 084738.pdf 2025.04.15 167.16kB