Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 302 SW CADENCE GLN
LAKE CITY, FL 32024
Parcel #: 03001-106
Acres: 1.14
Owner: Maronda Homes Llc Of Florida
Subdivision: Forest Cove
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 69739
Permit #: 000052688
Related Permit:
Submitted: Tuesday, March 11, 2025
Issued: Monday, March 24, 2025
Expires: Monday, July 21, 2025
Completed: Monday, July 21, 2025
Status: Completed
Septic Release? Yes
Notes:
*MFE = 1' ABOVE CROWN OF ROAD (102.8'), SURVEYOR CONFIRMATION REQUIRED, SURVEYOR CONFIRMATION REC'D @ 103.21' *AS BUILT SURVEY PRIOR TO CO PER PLAT FOR DRAINAGE SWALES AND LOT CONTOURS(REC'D)-- OK PER CHAD 7.21.25 MG *FINAL DRIVE AND SEPTIC RELEASE REQUIRED PRIOR TO RELEASE OF POWER *ASSESSMENTS OWED @ PERM POWER, BLOWER DOOR AND TERMITE FINAL REQUIRED PRIOR TO RELEASE OF CO
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 1' above the crown of the road (102.8')
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0289D
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 3130
Total Area (Sqft) 4126
Building Height 25
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0124
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
3/4/2025 Application pending.
3/11/2025 Application submitted by applicant.
3/13/2025 Point Review - Printed-Online Application
3/13/2025 Point Review - Reviewed
3/13/2025 Zoning Review - Reviewed
3/19/2025 Plan Review - Plumbing Approved
3/19/2025 Plan Review - Mechanical Approved
3/19/2025 Plan Review - Electrical Approved
3/19/2025 Plan Review - Building Approved
3/19/2025 Plan Review - Reviewed
3/19/2025 Final Review - Processing
3/20/2025 Final Review - Reviewed
3/20/2025 Final Review - Payment Needed
3/24/2025 Permit Issued
6/24/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Adam Gaslin
Maronda Homes Llc Of Florida
CRC1331630 Cert. Residential Contractor
Paul K Coleman
Colemans Plumbing Inc.
CFC1425624 Certified Plumbing Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Ryan Hinote
Nature Coast Electrical
EC13011934 Cert. Electrical Subcontractor
Robert M Bounds
Bounds Heating & Air Inc
CAC057642 Class A A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - 1st Underground Rough–In Matt Forsyth 3/31/2025
Passed: Electrical - Temporary Service Matt Forsyth 3/31/2025
Release to power company Matt Forsyth 3/31/2025
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 3/31/2025
Passed: Building - Monolithic Slab Matt Forsyth 4/7/2025
Passed: Engineering - Setbacks Matt Forsyth 4/7/2025
Passed: Building - Roof Decking Matt Forsyth 5/21/2025
Passed: Building - Wall Sheathing Matt Forsyth 5/21/2025
Cancelled: Building - Fire Rated Wall Troy Crews 5/21/2025
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 5/21/2025
Passed: Building - Insulation Walls Matt Forsyth 5/21/2025
Passed: Building - Framing Matt Forsyth 5/21/2025
Passed: Mechanical - Rough In Matt Forsyth 5/21/2025
Passed: Plumbing/Gas - Tub Set/Shower Pan Matt Forsyth 5/21/2025
Passed: Electrical - 2nd Rough-In Matt Forsyth 6/4/2025
Failed: Electrical - Permanent Power Work Not Complete Matt Forsyth 6/4/2025
Passed: Electrical - Permanent Power Final Drive(rec'd) Required Prior To Release Of Power-- 6.10.25 Mg Matt Forsyth 6/5/2025
Septic Release Inspection Health Dept 6/10/2025
Release to power company Final Septic Rec'd-- As-built Survey Required Prior To Co-- See Public Notes-- 6.19.25 Mg Melissa Garber 6/19/2025
Passed: Building - Final All Requirements Met, Chad Ok'd As-built-- 7.21.25 Mg Matt Forsyth 6/26/2025
Documents
File Name Date File Size