Roof Replacement or Repair
Permit
| Application #: | 70032 |
| Permit #: |
000052683 |
| Related Permit: |
|
| Submitted: | Friday, March 21, 2025 |
| Issued: | Monday, March 24, 2025 |
| Expires: | Tuesday, April 8, 2025 |
| Completed: | Tuesday, April 8, 2025 |
| Status: |
Completed |
| Septic Release? |
N/A |
Notes
PICS AND AFFIDAVIT REC'D
Job Details
| Finished floor requirement |
|
| Fema map number |
12023C0187D |
| Type Roofing Job |
Replacement - Tear off Existing and Replace |
| Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
re roof, remove & install 22 sq. shingles & 6 sq. Mod bit. pitch 5/12. |
| Type of structure |
House |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
28 |
| No. of Stories |
1 |
| Roof Pitch |
4:12 or Greater |
| Is the existing roof being removed? |
Yes |
| Type of New Roofing Product |
Asphalt Shingles |
| Florida Product Approval Number |
10674.1 |
| Other Roofing Product Type Not Listed |
Mod bit FL#2533.1 |
| Product Manufacturer |
Owens corning |
| Product Description |
duration |
| Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
| Sealed roof decking options: (Must select an option.) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
| Ventilation: |
Ridge Vent |
| Flashing: |
Replace with L-Flashing |
| Drip Edge: |
Replace All |
| Valley Treatment: |
New Metal |
| Second Roof Pitch (if applicable) |
Less than 2:12 |
| Any cable and/or race-way wiring located on or within the roof assembly? |
No |
Review Notes
| 3/21/2025 |
Application pending. |
| 3/21/2025 |
Application submitted by applicant. |
| 3/21/2025 |
Final Review - Corrections Needed |
| 3/24/2025 |
Final Review - Payment Needed |
| 3/24/2025 |
Permit Issued |
Contractors
| Name / Business |
License |
Title |
Role |
Derek S Williams Elo Restoration, Inc
|
CCC1331535 |
Cert. Roofing |
Contractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Passed: Re-Roof - In Progress |
Roof Complete, In The Future Please Be Advised We Do An In Progress Inspection The Day Your Company Starts Work And A Fiinal After Y?ou Are Completed |
Gary Pitzer |
4/7/2025 |
| Rescheduled 4/8/2025:Re-Roof - Final |
|
Gary Pitzer |
4/7/2025 |
| Passed: Re-Roof - Final |
|
Troy Crews |
4/8/2025 |
| Passed: Re-Roof - Final |
Vo. Per Photos And On Site Visit |
Gary Pitzer |
4/8/2025 |