Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 2382 SW BIRLEY AVE
LAKE CITY, FL 32024
Parcel #: 02817-000
Acres: 2.13
Owner: Joyner Charlene L
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 70026
Permit #: 000052662
Related Permit:
Submitted: Thursday, March 20, 2025
Issued: Friday, March 21, 2025
Expires: Thursday, April 10, 2025
Completed: Thursday, April 10, 2025
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) SFR, 28 sq, 6/12 pitch, Owens Coring shingle and underlayment
Type of structure House
Roof Area (for this job) Sq Ft 2800
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10674-R19
Product Manufacturer Owens Corning
Product Description Oakridge
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0290D
Review Notes
3/20/2025 Application pending.
3/20/2025 Application submitted by applicant.
3/20/2025 Final Review - Payment Needed
3/21/2025 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Chase Massey
Massey Roofing Services Llc
CCC1332486 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Failed: Re-Roof - In Progress No Work Being Done Troy Crews 4/1/2025
Cancelled: Re-Roof - In Progress Neonta Anderson 4/2/2025
Cancelled: Re-Roof - In Progress Neonta Anderson 4/2/2025
Passed: Re-Roof - In Progress Matt Forsyth 4/7/2025
Passed: Re-Roof - Final Matt Forsyth 4/10/2025