Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 237 SW BARON GLN
FORT WHITE, FL 32038
Parcel #: 03752-402
Acres: 4.77
Owner: Lucier Timothy Glen,
Subdivision: Southern Meadows Phase 1
Zoning: A-3
Flood Zone: X
District: 4
Application #: 69987
Permit #: 000052641
Related Permit:
Submitted: Wednesday, March 19, 2025
Issued: Wednesday, March 19, 2025
Expires: Wednesday, March 26, 2025
Completed: Wednesday, March 26, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replacing any rotted decking with likewise 1/2 inch plywood
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 3200
No. of Stories 1
Ventilation: Off-ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Second Roof Pitch (if applicable) Less than 2:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10674-R19
Product Manufacturer Owens Corning
Product Description Asphalt shingles
Other Roofing Product Type Not Listed Certainteed Modifed Bitumen on low slope FL2533-R19
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Sealed roof decking explanation for other option. self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire low slope roof
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0390C
Review Notes
3/19/2025 Application pending.
3/19/2025 Application submitted by applicant.
3/19/2025 Final Review - Payment Needed
3/19/2025 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Eric L Mccullar
Rooftop Restorations Inc
RC29027863 Reg. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Gary Pitzer 3/25/2025
Passed: Re-Roof - Final Roof Vents, Shingle Roof Covering On Manufactured Home, Please Remember In The Future To Schedule An In Progress Inspection On The Day Of Tear Off, This Is A Required Inspection For Columbia County Gary Pitzer 3/26/2025