Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Storage Building Permit
Address 644 SW MIRACLE CT
LAKE CITY, FL 32024
Parcel #: 02789-018
Acres: 4.02
Owner: Herrero Humberto A, Herrero Gaye
Subdivision: Joy Estates
Zoning: A-3
Flood Zone: X
District: 2
Application #: 69678
Permit #: 000052637
Related Permit: Right-of-Way Access/Driveway: 000052629
Submitted: Thursday, February 27, 2025
Issued: Tuesday, March 18, 2025
Expires: Tuesday, September 23, 2025
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:
*NON-HABITABLE STORAGE *NEW SLAB, NO MEP
Job Details
Type of Structure Garage
Commercial or Residential? Residential
Slab New
Mechanical No
Electrical No
Plumbing No
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setback Rear 10' (accessory)
Length 65'
Width 30'
Total Area (Sqft) 1950
Building Height 5' on center
Septic# (00-0000) or (X00-000) 25-0188
Dev Permit # F023-
Building Code Construction Type III
Building Code Element B
Building Code Occupancy Types Storage
Occupancy Use Title non-habitable storage
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Elevation regulation Accessory Use
Finished floor requirement Non-Habitable Structure
Fema map number 12023C0290D
Review Notes
2/27/2025 Application pending.
2/27/2025 Application submitted by applicant.
2/28/2025 Point Review - Processing NEED * SEPTIC#
3/11/2025 Point Review - Printed-Online Application NEEDED: *DRIVE APPROVAL-- SEE APP #69866 *OWNER BUILDER DISCLOSURE STATEMENT MISSING NOTARY STAMP *THERE ARE 2 DIFFERENT SETS OF METAL BUILDING PLANS, PLEASE CONFIRM WHICH IS THE CORRECT ONE-- ADAM COLLINS OR TRAVIS COVINGTON *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386.758.1058
3/11/2025 Point Review - Reviewed NEEDED: *DRIVE APPROVAL-- SEE APP #69866 *OWNER BUILDER DISCLOSURE STATEMENT MISSING NOTARY STAMP *THERE ARE 2 DIFFERENT SETS OF METAL BUILDING PLANS, PLEASE CONFIRM WHICH IS THE CORRECT ONE-- ADAM COLLINS OR TRAVIS COVINGTON *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386.758.1058
3/11/2025 Zoning Review - Reviewed NEEDED: *DRIVE APPROVAL-- SEE APP #69866 *OWNER BUILDER DISCLOSURE STATEMENT MISSING NOTARY STAMP *THERE ARE 2 DIFFERENT SETS OF METAL BUILDING PLANS, PLEASE CONFIRM WHICH IS THE CORRECT ONE-- ADAM COLLINS OR TRAVIS COVINGTON *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386.758.1058
3/14/2025 Plan Review - Reviewed NEEDED: *DRIVE APPROVAL-- SEE APP #69866
3/14/2025 Final Review - Processing NEEDED: *DRIVE APPROVAL-- SEE APP #69866
3/18/2025 Final Review - Payment Needed
3/18/2025 Permit Issued Permit # created and approved from payment.
Contractors

This is an owner builder project.

Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 3/14/2025
Failed: Building - Footer 2#4 Bar Needed In Footing Matt Forsyth 3/20/2025
Passed: Engineering - Setbacks Matt Forsyth 3/20/2025
Passed: Building - Footer Matt Forsyth 3/27/2025
Passed: Engineering - Setbacks Matt Forsyth 3/27/2025