Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 1076 SW HIGH FIELD TER
LAKE CITY, FL 32024
Parcel #: 03761-158
Acres: 5.00
Owner: Steven Mcmahon
Subdivision: Meadowlands Phase 4
Zoning: A-3
Flood Zone: X
District: 4
Application #: 69955
Permit #: 000052613
Related Permit:
Submitted: Monday, March 17, 2025
Issued: Monday, March 17, 2025
Expires: Wednesday, April 2, 2025
Completed: Wednesday, April 2, 2025
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Tear off existing shingles and replacing with new shingles
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 38
No. of Stories 1
Ventilation: Off-ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL 10674 R19
Product Manufacturer Owens Corning
Product Description architectural shingles
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0395C
Review Notes
3/17/2025 Application pending.
3/17/2025 Application submitted by applicant.
3/17/2025 Final Review - Payment Needed NEEDED * NOC HAS THE WRONG PARCEL # THEY OWN BOTH 03761-157 & 03761-B158 BUT THE HOUSE IS ON 03761-158 NOC IS RECORDED ON 03761-157
3/17/2025 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Joshua Lewis
Retex Roofing Fl Llc
CCC1333219 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Gary Pitzer 3/27/2025
Passed: Re-Roof - Final Dem Shingle Roof Covering With Off Ridge Vent, Appears To Be New New Flashing On Plumbing Stacks Gary Pitzer 4/2/2025