Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 1414 NW JOSEPHINE ST
LAKE CITY, FL 32055
Parcel #: 04804-112
Acres: 17.82
Owner: Lunsford Donald Lee Iii, Lunsford Haley Diane
Subdivision: Falling Creek Farms- Division Of Land
Zoning: A-3
Flood Zone: X
District: 1
Application #: 69015
Permit #: 000052524
Related Permit:
Submitted: Friday, January 17, 2025
Issued: Friday, March 7, 2025
Expires: Wednesday, January 14, 2026
Completed:
Status: Permit Issued
Septic Release? No
Notes:

Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0195D
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1605
Total Area (Sqft) 2293
Building Height 22
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0039
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
1/16/2025 Application pending.
1/17/2025 Application submitted by applicant.
2/3/2025 Point Review - Printed-Online Application NEEDED: *CONTRACTOR AUTHORIZATION FOR KERRI CLARK *SEALED STRUCTURAL PLANS *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY
2/3/2025 Point Review - Reviewed NEEDED: *CONTRACTOR AUTHORIZATION FOR KERRI CLARK *SEALED STRUCTURAL PLANS *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY
2/3/2025 Zoning Review - Reviewed NEEDED: *CONTRACTOR AUTHORIZATION FOR KERRI CLARK *SEALED STRUCTURAL PLANS *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED
2/3/2025 Plan Review - Documents Required NEEDED: *CONTRACTOR AUTHORIZATION FOR KERRI CLARK *SEALED STRUCTURAL PLANS *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED
2/3/2025 Plan Review - Documents Required NEEDED: *CONTRACTOR AUTHORIZATION FOR KERRI CLARK *SEALED STRUCTURAL PLANS *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED-- CONTACT THE OFFICE TO DISCUSS SITE PLAN CHANGES -- MG
2/10/2025 Plan Review - Plumbing Approved NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED-- CONTACT THE OFFICE TO DISCUSS SITE PLAN CHANGES -- MG
2/10/2025 Plan Review - Mechanical Approved NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED-- CONTACT THE OFFICE TO DISCUSS SITE PLAN CHANGES -- MG
2/10/2025 Plan Review - Electrical Approved NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED-- CONTACT THE OFFICE TO DISCUSS SITE PLAN CHANGES -- MG
2/10/2025 Plan Review - Building Approved NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED-- CONTACT THE OFFICE TO DISCUSS SITE PLAN CHANGES -- MG
2/10/2025 Plan Review - Reviewed NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED-- CONTACT THE OFFICE TO DISCUSS SITE PLAN CHANGES -- MG
2/10/2025 Final Review - Documents Required NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058 *SIGNED MECHANICAL SUBFORM-- EC LISTED FOR MECHANICAL CURRENTLY *MG TO CONFIRM 911 ADDRESS, AS SITE PLAN HAS SHIFTED-- CONTACT THE OFFICE TO DISCUSS SITE PLAN CHANGES -- MG
2/20/2025 Final Review - Documents Required NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058
2/27/2025 Final Review - Documents Required NEEDED: *ENV HEALTH APPROVAL-- CONTACT 386.758.1058
3/5/2025 Final Review - Reviewed
3/5/2025 Final Review - Payment Needed
3/7/2025 Permit Issued Permit #000052524 created and approved.
Contractors
Name/ Business License Title Role
Ronnie Edenfield
Scci Inc
CBC1267457 Cert. Building Contractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Don C Bills Sr
Hometown Plumbing Services Llc
CFC1428890 Plumbing Contractor Subcontractor
Ralph W Laverdure
Rwl Roofing Llc
CCC1328590 Roofing Contractor Subcontractor
Donald R Davis
High Springs Electric Inc
CAC1815367 Class B A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Put Ground Wire On Steel Prior To Pour Troy Crews 6/17/2025
Passed: Engineering - Setbacks Troy Crews 6/17/2025
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 7/15/2025
Passed: Building - Slab Anthony Aslan 7/18/2025
Documents
File Name Date File Size
52524 Compaction (2).jpg 2025.07.21 409.83kB
52524 Compaction.jpg 2025.07.21 614.54kB
Original Permit 20250307.pdf 2025.07.05 32.11kB
Approved Site Plan 69015.pdf 2025.07.05 174.69kB
Falling Creek Farms - Division Of Land Lot 12.pdf 2025.06.26 5.97MB
Recorded Notice Of Commencement 20250117 100731.pdf 2025.06.23 59.84kB
Energy Code Forms 20250117 100728.pdf 2025.06.22 92.01kB
Property Appraiser Parcel Details Printed Page 20250117 100730.pdf 2025.06.22 147.44kB
911 Address Form 20250117 100726.pdf 2025.06.22 217.40kB
Manual J Forms 20250117 100730.pdf 2025.06.22 113.36kB
Lunsford _ S.1.pdf 2025.06.21 988.79kB
Approved S-1 69015 2025-02-10 08.32.55.271.pdf 2025.06.21 1,021.90kB
Lunsford _ S.2.pdf 2025.06.21 1.23MB
Approved S-2 69015 2025-02-10 08.33.18.23.pdf 2025.06.21 1.27MB
Subcontractor Form 20250303 143850v1.pdf 2025.03.03 132.57kB
Lunsford Eh 25-0039.pdf 2025.03.03 647.06kB
Lunsford Updated Siteplan.pdf 2025.02.20 27.68kB
Approved Truss Plans 69015 2025-02-10 08.34.31.299.pdf 2025.02.10 723.23kB
Approved S-4 69015 2025-02-10 08.34.04.346.pdf 2025.02.10 795.77kB
Approved S-3 69015 2025-02-10 08.33.38.224.pdf 2025.02.10 1.72MB
Lunsford _ S.4.pdf 2025.02.04 758.08kB
Lunsford _ S.3.pdf 2025.02.04 1.68MB
Srwmd Enhanced Snapshot 69015.pdf 2025.02.03 619.49kB
Recorded Deed.pdf 2025.02.03 358.30kB
Truss Engineering 20250130 150257.pdf 2025.01.30 654.26kB
Product Approval Code Specifications Form 20250117 101000.pdf 2025.01.17 99.74kB
Residential Or Commercial Checklist 20250117 100731.pdf 2025.01.17 592.77kB
Floodplain Ordinance Notice To Owner 20250117 100729.pdf 2025.01.17 139.69kB
Owner And Contractor Signature Page 20250117 094358.pdf 2025.01.17 125.99kB