Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 141 SW EMORYWOOD GLN
LAKE CITY, FL 32024
Parcel #: 03397-205
Acres: 1.68
Owner: Sweenor Joseph Monroe, Sweenor Diane Renee
Subdivision: Cove At Rose Creek
Zoning: A-3
Flood Zone: X
District: 5
Application #: 69659
Permit #: 000052494
Related Permit:
Submitted: Tuesday, March 4, 2025
Issued: Tuesday, March 4, 2025
Expires: Sunday, August 31, 2025
Completed:
Status: Permit Issued
Septic Release? na
Notes:

Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Tear-off Re-roof 34sq Arch Shingles FL10674
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 3400
No. of Stories 2
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Roof Pitch 4:12 or Greater
Second Roof Pitch (if applicable) 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10674
Product Manufacturer Owens Corning
Product Description Duration
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Fema map number 12023C0383D
Review Notes
2/26/2025 Application pending.
3/4/2025 Application submitted by applicant.
3/4/2025 Final Review - Payment Needed
3/4/2025 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
Barbara J Ifft
Evergreen Roofing And Solar
Liability Insurance Expired.
CCC1335371 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date