Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 312 SW THISTLEWOOD LN
FORT WHITE, FL 32038
Parcel #: 04056-122
Acres: 1.11
Owner: Terry Craig A, Terry Lisa
Subdivision: Thornwood
Zoning:
Flood Zone: X
District: 2
Application #: 67674
Permit #: 000052414
Related Permit: Right-of-Way Access/Driveway: 000052324
Submitted: Thursday, November 14, 2024
Issued: Friday, February 21, 2025
Expires: Tuesday, July 29, 2025
Completed: Tuesday, July 29, 2025
Status: Completed
Septic Release? Yes
Notes:
*MFE = 12" ABOVE THE ADJACENT GROUND FOR THE ENTIRE PEIMETER OF THE FOUNDATION
Job Details
Finished floor requirement
Fema map number 12023C0292D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 21.20
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL35321
Product Manufacturer Tamko
Product Description Rustic Cedar
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Off-ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
10/21/2024 Application pending.
1/14/2025 Application submitted by applicant.
2/3/2025 Point Review - Printed-Online Application NEEDED" *OWNER AND CONTRACTOR SIGNATURE PAGE SIGNED BY OWNER AND CONTRACTOR *UPDATED SITE PLAN TO REFLECT 25' MINIMUM SIDE SETBACK-- SEE TOWN OF FORT WHITE COMPLIANCE LETTER ***PRIOR TO INSPECTIONS*** RECORDED NOC
2/3/2025 Point Review - Reviewed NEEDED" *OWNER AND CONTRACTOR SIGNATURE PAGE SIGNED BY OWNER AND CONTRACTOR *UPDATED SITE PLAN TO REFLECT 25' MINIMUM SIDE SETBACK-- SEE TOWN OF FORT WHITE COMPLIANCE LETTER ***PRIOR TO INSPECTIONS*** RECORDED NOC
2/3/2025 Zoning Review - Corrections Needed NEEDED" *OWNER AND CONTRACTOR SIGNATURE PAGE SIGNED BY OWNER AND CONTRACTOR *UPDATED SITE PLAN TO REFLECT 25' MINIMUM SIDE SETBACK-- SEE TOWN OF FORT WHITE COMPLIANCE LETTER ***PRIOR TO INSPECTIONS*** RECORDED NOC
2/6/2025 Plan Review - Documents Required NEEDED: *DRIVEWAY APPROVAL *OWNER AND CONTRACTOR SIGNATURE PAGE SIGNED BY OWNER AND CONTRACTOR *UPDATED SITE PLAN TO REFLECT 25' MINIMUM SIDE SETBACK-- SEE TOWN OF FORT WHITE COMPLIANCE LETTER NEED SEALED PLANS DIGITAL SEAL CORRUPTED ***PRIOR TO INSPECTIONS*** RECORDED NOC
2/10/2025 Plan Review - Documents Required NEEDED: *DRIVEWAY APPROVAL *OWNER AND CONTRACTOR SIGNATURE PAGE SIGNED BY OWNER AND CONTRACTOR *UPDATED SITE PLAN TO REFLECT 25' MINIMUM SIDE SETBACK-- SEE TOWN OF FORT WHITE COMPLIANCE LETTER NEED SEALED PLANS DIGITAL SEAL CORRUPTED ***PRIOR TO INSPECTIONS*** RECORDED NOC
2/13/2025 Zoning Review - Town of Ft. White NEEDED: *NEED SEALED PLANS DIGITAL SEAL CORRUPTED
2/13/2025 Plan Review - Documents Required NEEDED: *NEED SEALED PLANS DIGITAL SEAL CORRUPTED
2/13/2025 Plan Review - Documents Required NEEDED: *NEED SEALED PLANS DIGITAL SEAL CORRUPTED
2/20/2025 Plan Review - Plumbing Approved NEEDED:
2/20/2025 Plan Review - Mechanical Approved NEEDED:
2/20/2025 Plan Review - Electrical Approved NEEDED:
2/20/2025 Plan Review - Building Approved NEEDED:
2/20/2025 Plan Review - Reviewed NEEDED:
2/20/2025 Final Review - Processing NEEDED:
2/20/2025 Final Review - Reviewed
2/20/2025 Final Review - Payment Needed
2/21/2025 Permit Issued Permit #000052414 created and approved.
6/19/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Jeffrey P Bokor
Dwc Contracting Llc
CGC1517145 General Contractor Contractor
James Butler Jr
Butler Plumbing Of Gainesville Inc
CFC057960 Plumbing Contractor Subcontractor
Jeffrey Bokor
Dwc Contracting Llc
CCC1329756 Roofing Contractor Subcontractor
Ryan C Beville
Rbi Electrical Contracting Llc
Employees Workers Comp Expired.
EC13004236 Electrical Contractor Subcontractor
Samuel L Roberts
Air Ducks Inc
Employees Workers Comp Expired.
CAC1817288 Class "b" A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 2/25/2025
Rescheduled 3/5/2025:Building - Monolithic Slab Troy Crews 3/4/2025
Cancelled: Engineering - Setbacks Troy Crews 3/4/2025
Passed: Building - Monolithic Slab Need Permit Box termite Spray Ticket Anthony Aslan 3/5/2025
Passed: Engineering - Setbacks Appears Within Setbacks Anthony Aslan 3/5/2025
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 3/20/2025
Passed: Building - Roof Decking Anthony Aslan 3/20/2025
Passed: Electrical - Temporary Service Troy Crews 3/26/2025
Release to power company Troy Crews 3/26/2025
Passed: Electrical - 2nd Rough-In Troy Crews 4/2/2025
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 4/2/2025
Passed: Mechanical - Rough In Reminder Need To Request A Framing Inspection Prior To Insulation Troy Crews 4/7/2025
Passed: Building - Framing Dryer Vent Nail Guard Check At Insulation Anthony Aslan 4/9/2025
Passed: Building - Insulation Walls Only Anthony Aslan 4/14/2025
Passed: Electrical - Permanent Power Need Septic Release Anthony Aslan 6/4/2025
Release to power company Rec'd Septic Emaleigh Williams 6/18/2025
Septic Release Inspection Health Dept 6/18/2025
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 7/8/2025
Passed: Building - Final All Requirements Met To Release Co-- 7.29.25 Mg Anthony Aslan 7/29/2025
Documents
File Name Date File Size