Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 281 SW MARKS DR
LAKE CITY, FL 32024
Parcel #: 02752-000
Acres: 1.78
Owner: Fortunas Timothy Alexander
Subdivision: Westwood Acres
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 69466
Permit #: 000052378
Related Permit:
Submitted: Tuesday, February 18, 2025
Issued: Wednesday, February 19, 2025
Expires: Thursday, April 24, 2025
Completed: Thursday, April 24, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0290D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Shingle reroof, Replacing exterior wall and interior wall and 2 trusses
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 31
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL30310-R5
Product Manufacturer IKO Industries Ltd
Product Description Asphalt Shingles
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: Use Existing
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
2/13/2025 Application pending.
2/18/2025 Application submitted by applicant.
2/18/2025 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS,.
2/18/2025 Final Review - Payment Needed
2/19/2025 Permit Issued Permit # created and approved from payment.
4/1/2025 Plan Review - Documents Required TRUSS PLANS MUST BE SEALED
Contractors
Name/ Business License Title Role
Tristan J Hall
J&m Residential Services Florida Division, Llc
CCC1331951 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Decking In Area Of Repair Ok Need To Do Framing Inspection From Interior Prior To Sheetrock Troy Crews 4/4/2025
Passed: Building - Framing Installed New Trusses In Damaged Area Where Needed Held With Simpson Screws Troy Crews 4/15/2025
Passed: Re-Roof - In Progress Tearing Off Shingles And Underlayment With New Underlayment Going Down Troy Crews 4/15/2025
Passed: Re-Roof - Final Troy Crews 4/24/2025
Documents
File Name Date File Size