Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 377 SE DEERWOOD GLN
LAKE CITY, FL 32025
Parcel #: 08302-117
Acres: 1.03
Owner: Martin Leofus A,
Subdivision: Deerwood Forest Unit 2
Zoning: RSF-2
Flood Zone: AH
District: 5
Application #: 64738
Permit #: 000052004
Related Permit: Floodplain Development Permit: FDP2025-003
Submitted: Friday, March 29, 2024
Issued: Tuesday, January 7, 2025
Expires: Saturday, November 15, 2025
Completed:
Status: Zoning Review - Reviewed
Septic Release? No
Notes:
*ZONING: MFE = 104.5' **FINAL CONSTRUCTION ELEVATION CERTIFICATE REQUIRED PRIOR TO PERMANANT POWER.
LAKE CITY UTLITY CUSTOMER SERVICE NOTES The City of Lake City's Utility Department approved a tap application for water service.
Job Details
Elevation regulation Special Flood Hazard Area
Finished floor requirement 104.5' One foot above FEMA Map Elevation
Requirement needed By Permanent Power Inspection
Document needed is an Elevation Certificate for Finished Construction
Document receieved No
Fema map number 12023C0313D
Water source Sante Fe
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 1466
Total Area (Sqft) 2075
Building Height 16
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 24-0464
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
3/29/2024 Application pending.
3/29/2024 Application submitted by applicant.
3/29/2024 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_WATER,.
4/8/2024 Point Review - On Hold-Incomplete NEEDED: *EDENFIELD TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *LICENSE NUMBER FOR HIGH SPRINGS ELECTRIC NOT REGISTERED--- EITHER CORRECT NUMBER OR REGISTER THAT LICENSE NUMBER ON SUBFORM AND IN PORTAL *911 ADDRESS-- PLEASE APPLY ONLINE *OWNERS PHONE # *CONTRACTOR AUTHORIZATION FOR KERRI *ENV HEALTH-- CONTACT 386-758-1058 *SEALED ARCHITECTURAL/STRUCTURAL PLANS *MANUAL J AND ENERGY CALCS *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING
4/11/2024 Point Review - On Hold-Incomplete NEEDED: *EDENFIELD TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *LICENSE NUMBER FOR HIGH SPRINGS ELECTRIC NOT REGISTERED--- EITHER CORRECT NUMBER OR REGISTER THAT LICENSE NUMBER ON SUBFORM AND IN PORTAL *911 ADDRESS-- PLEASE APPLY ONLINE *OWNERS PHONE # *ENV HEALTH-- CONTACT 386-758-1058 *SEALED ARCHITECTURAL/STRUCTURAL PLANS *MANUAL J AND ENERGY CALCS *RESIDENTIAL CHECKLIST *SIGNED SUBCONTRACTOR FORM FOR MECHANICAL, ROOFING, AND PLUMBING *TRUSS ENGINEERING
5/14/2024 Point Review - On Hold-Incomplete NEEDED: *EDENFIELD TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *ENV HEALTH-- CONTACT 386-758-1058 *OWNERS PHONE NUMBER *SEALED ARCHITECTURAL/STRUCTURAL PLANS *MANUAL J AND ENERGY CALCS *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING *1' RISE CERTIFICATION ** 2 ELEVATION CERTIFICATES WILL BE REQUIRED--PROPOSED FINISHED FLOOR ELEVATION AND FINAL.
5/17/2024 Point Review - On Hold-Incomplete NEEDED: *EDENFIELD TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *ENV HEALTH-- CONTACT 386-758-1058 *OWNERS PHONE NUMBER *SEALED ARCHITECTURAL/STRUCTURAL PLANS *MANUAL J AND ENERGY CALCS *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING *1' RISE CERTIFICATION ** 2 ELEVATION CERTIFICATES WILL BE REQUIRED--PROPOSED FINISHED FLOOR ELEVATION AND FINAL.
5/30/2024 Point Review - Printed-Online Application NEEDED: *EDENFIELD TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *ENV HEALTH-- CONTACT 386-758-1058 *OWNERS PHONE NUMBER *MANUAL J AND ENERGY CALCS *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING *1' RISE CERTIFICATION ** 2 ELEVATION CERTIFICATES WILL BE REQUIRED--PROPOSED FINISHED FLOOR ELEVATION AND FINAL.
5/31/2024 Zoning Review - Documents Required NEEDED: *EDENFIELD TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *ENV HEALTH-- CONTACT 386-758-1058 *OWNERS PHONE NUMBER *MANUAL J AND ENERGY CALCS *RESIDENTIAL CHECKLIST *TRUSS ENGINEERING ZONING: MFE = 104.5' DUE TO SPECIAL FLOOD HAZARD AREA * 2 ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTION BASED AND FINAL CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED IF FILL DIRT IS BROUGHT IN. CONFIRM REQUIREMENTS OF SRWMD FOR FILL DIRT STAFF: DEV PERMIT FEE
7/10/2024 Zoning Review - Documents Required NEEDED: *EDENFIELD TO COMPLETE REGISTRATION-- CONTACT 386-758-1008 FOR DETAILS *ENV HEALTH-- CONTACT 386-758-1058 *OWNERS PHONE NUMBER *RESIDENTIAL CHECKLIST ZONING: MFE = 104.5' DUE TO SPECIAL FLOOD HAZARD AREA * 2 ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTION BASED AND FINAL CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED IF FILL DIRT IS BROUGHT IN. CONFIRM REQUIREMENTS OF SRWMD FOR FILL DIRT STAFF: DEV PERMIT FEE
8/22/2024 Zoning Review - Documents Required ZONING: MFE = 105.5' DUE TO SPECIAL FLOOD HAZARD AREA * 2 ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTION BASED AND FINAL CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED IF FILL DIRT IS BROUGHT IN. STAFF: DEV PERMIT FEE
10/1/2024 Zoning Review - Documents Required ZONING: MFE = 105.5' DUE TO SPECIAL FLOOD HAZARD AREA * 3 ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTION BASED, UNDER CONSTRUCTION AND A FINAL CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED IF FILL DIRT IS BROUGHT IN. STAFF: DEV PERMIT FEE
10/7/2024 Zoning Review - Documents Required ZONING: MFE = 105.5' DUE TO SPECIAL FLOOD HAZARD AREA * 3 ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTION BASED, UNDER CONSTRUCTION AND A FINAL CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED IF FILL DIRT IS BROUGHT IN. STAFF: DEV PERMIT FEE
10/7/2024 Point Review - Printed-Online Application ZONING: MFE = 105.5' DUE TO SPECIAL FLOOD HAZARD AREA * 3 ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTION BASED, UNDER CONSTRUCTION AND A FINAL CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED IF FILL DIRT IS BROUGHT IN. STAFF: DEV PERMIT FEE
11/4/2024 Zoning Review - Documents Required ZONING: MFE = 105.5' DUE TO SPECIAL FLOOD HAZARD AREA * 3 ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTION BASED, UNDER CONSTRUCTION AND A FINAL CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED IF FILL DIRT IS BROUGHT IN. * FLOODPLAIN ORDINANCE NOTICE TO OWNER - THIS FORM CAN BE FOUND ON THE WEBSITE UNDER THE DOCUMENTS TAB STAFF: DEV PERMIT FEE
11/5/2024 Zoning Review - Documents Required ZONING: MFE = 105' DUE TO SPECIAL FLOOD HAZARD AREA BFE OF 104' *(3) ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTIN DRAWINGS, UNDER CONSTRUCTION AND FINAL CONSTRUCTION CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED WITH FILL DIRT BROUGHT IN. * FLOODPLAIN ORDINANCE NOTICE TO OWNER - THIS FORM CAN BE FOUND ON THE WEBSITE UNDER THE DOCUMENTS TAB STAFF: DEV PERMIT FEE
12/3/2024 Zoning Review - Documents Required ZONING: MFE = 105' DUE TO SPECIAL FLOOD HAZARD AREA BFE OF 104' *(3) ELEVATION CERTIFICATES WILL BE REQUIRED-- CONSTRUCTIN DRAWINGS, UNDER CONSTRUCTION AND FINAL CONSTRUCTION CERTIFICATES. * 1' RISE CERTIFICATION LETTER REQUIRED WITH FILL DIRT BROUGHT IN. * FLOODPLAIN ORDINANCE NOTICE TO OWNER - THIS FORM CAN BE FOUND ON THE WEBSITE UNDER THE DOCUMENTS TAB STAFF: DEV PERMIT FEE
12/12/2024 Zoning Review - Documents Required ZONING: PRIOR TO PERMITTING: * 1' RISE CERTIFICATION LETTER REQUIRED WITH FILL DIRT BROUGHT IN.
1/6/2025 Zoning Review - Reviewed ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION EC IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Zoning Review - Reviewed ZONING: PLEASE PROVIDE THE ORIGINAL CONSTRUCTION PLAN-BASED ELEVATION CERTIFICATE WITH THE SQUEEZED SEAL. UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION EC IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Plan Review - Documents Required ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5' STRUCTURAL PLANS SEAL SHOWES CORRUPTED E-MAIL NEW SET
1/6/2025 Plan Review - Plumbing Approved ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Plan Review - Mechanical Approved ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Plan Review - Electrical Approved ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Plan Review - Building Approved ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Plan Review - Reviewed ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Final Review - Processing ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Final Review - Reviewed ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/6/2025 Final Review - Payment Needed ZONING: UNDER-CONSTRUCTION ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO POURING THE SLAB. FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5'
1/7/2025 Permit Issued Permit #000052004 created and approved.
3/6/2025 Zoning Review - Documents Required ZONING: *COMPACTION TEST REPORT IS REQUIRED PRIOR TO ANY FURTHER INSPECTIONS. *WE NEED AN ORIGINAL SIGN/SEALED COPY OF THE UNDER-CONSTRUCTION ELEVATION CERTIFICATE *FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5' FLOOD VENT INFORMATION TO BE INCLUDED.
3/6/2025 Zoning Review - Email Sent ZONING: *FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5' FLOOD VENT INFORMATION TO BE INCLUDED. FLOOD VENTS LOCATED ON 2 OPPOSING SIDES OF THE GARAGE AND NO HIGHER THAN 12 INCHES ABOVE THE ADJACENT GRADE. UNDER-CONSTRUCTION EC AND COMPACTION REPORT RECEIVED 3-6-2025
7/2/2025 Zoning Review - Reviewed ZONING: *FINAL CONSTRUCTION ELEVATION CERTIFICATE IS REQUIRED PRIOR TO PERMENANT POWER INSPECTION. MFF: 104.5' FLOOD VENT INFORMATION TO BE INCLUDED. FLOOD VENTS LOCATED ON 2 OPPOSING SIDES OF THE GARAGE AND NO HIGHER THAN 12 INCHES ABOVE THE ADJACENT GRADE. UNDER-CONSTRUCTION EC AND COMPACTION REPORT RECEIVED 3-6-2025
Contractors
Name/ Business License Title Role
Don C Bills Sr
Hometown Plumbing Services Llc
CFC1428890 Plumbing Contractor Subcontractor
Ralph W Laverdure
Rwl Roofing Llc
CCC1328590 Roofing Contractor Subcontractor
Stephen M Brisbois
Epic Ac Service (dba) Central Home Heating & Air Llc
Workers Comp Expired.
CAC1819412 Cert. A/c Class “b” Subcontractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Ronnie Edenfield
Scci Inc
CBC1267457 Cert. Building Contractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Compaction Test Required Prior To Slab Being Poured Anthony Aslan 1/23/2025
Passed: Engineering - Setbacks Appears Within Setbacks Anthony Aslan 1/23/2025
Passed: Electrical - Temporary Service Anthony Aslan 1/23/2025
Release to power company Anthony Aslan 1/23/2025
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 2/24/2025
Passed: Building - Slab Compaction Test Rec'd Anthony Aslan 3/7/2025
Passed: Building - Roof Decking Anthony Aslan 3/27/2025
Passed: Building - Wall Sheathing Anthony Aslan 3/27/2025
Cancelled: Building - Ext Strapping/Wall Sheathing Anthony Aslan 5/6/2025
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 5/6/2025
Passed: Building - Framing Anthony Aslan 5/6/2025
Passed: Electrical - 1st Underground Rough–In Exhaust Fans Wire Not Connected Anthony Aslan 5/6/2025
Failed: Mechanical - Rough In Ducts Over And In Attic Access Anthony Aslan 5/6/2025
Cancelled: Building - Strapping Anthony Aslan 5/19/2025
Passed: Electrical - 2nd Rough-In Corrections Made Anthony Aslan 5/19/2025
Passed: Mechanical - Rough In Corrections Made Anthony Aslan 5/19/2025
Passed: Building - Insulation Walls Only Anthony Aslan 5/19/2025
Documents
File Name Date File Size