- Finished floor requirement
-
- Fema map number
- 12023C0382D
- Type Roofing Job
- Replacement - Tear off Existing and Replace
- Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
- Only replacing damaged wood
- Type of structure
- Mobile Home
- Commercial or Residential
- Residential
- Roof Area (for this job) Sq Ft
- 18.5
- No. of Stories
- 1
- Roof Pitch
- 2:12 to 4:12
- Is the existing roof being removed?
- Yes
- Type of New Roofing Product
- Metal
- Florida Product Approval Number
- FL28363.2
- Product Manufacturer
- Deep South Metals
- Product Description
- South Rib 3' Coverage 26-Ga. and 29-Ga.
- Building Code Edition
- 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
- Sealed roof decking options: (Must select an option.)
- two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
- Ventilation:
- Unvented
- Flashing:
- Replace All
- Drip Edge:
- Replace All
- Valley Treatment:
- New Metal
- Any cable and/or race-way wiring located on or within the roof assembly?
- No