Permit Details

Permit Search

Permit

Roof Replacement or Repair

218 SW GOLDEN DAWN GLN
HIGH SPRINGS, FL 32643

Permit #
000051920
Application #
67977
Status Completed
  1. Submitted Nov 6, 2024
  2. Issued Mar 31, 2025
  3. Expires Oct 8, 2025
  4. Completed Apr 11, 2025

Property

Parcel #
10057-000
Owner
Board Of Trustees Of The Internal Improvement Trust Fund Of The State Of Florida
Acres
25.25
Subdivision
—
Zoning
CSV
Flood zone
AE
District
4

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0551C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Decking will only be replaced only if needed once existing roof is torn off.
Type of structure
Mobile Home
Commercial or Residential
Commercial
Roof Area (for this job) Sq Ft
1550
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
Florida Product Approval # 17992.2 R4
Product Manufacturer
Capital Metals
Product Description
R-Panels Metal Roof
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
Other (explain)
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Documents Required
  4. Final Review - Documents Required
  5. Final Review - Documents Required
  6. Final Review - Payment Needed
  7. Final Review - Payment Needed
  8. Permit Issued
  9. Permit Reissued

Contractors

  • Jefferey L Ganskop

    Old World Craftsmen,inc.

    License
    CCC057557
    Title
    Cert Roofing
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. Dec 31, 2024

    Cancelled: Re-Roof - In Progress

    Inspected by Anthony Aslan

  2. Apr 11, 2025

    Passed: Re-Roof - In Progress

    Roof Complete

    Inspected by Anthony Aslan

  3. Apr 11, 2025

    Passed: Re-Roof - Final

    Inspected by Anthony Aslan