Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 19902 S US HIGHWAY 441
HIGH SPRINGS, FL 32643
Parcel #: 09886-004
Acres: 2.10
Owner: Mcknight Lindsey Nicole
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 68514
Permit #: 000051916
Related Permit:
Submitted: Sunday, December 15, 2024
Issued: Sunday, December 22, 2024
Expires: Wednesday, January 22, 2025
Completed: Wednesday, January 22, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0511C
Type Roofing Job Overlay with Metal
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) 1x4 purlins fastened with screws to roof stucture
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 20
No. of Stories 1
Roof Pitch 2:12 to 4:12
Is the existing roof being removed? No
Explain if not removing the existing roofing material? purlins installed over existing
Type of New Roofing Product Metal
Product Manufacturer tri county
Product Description 26 ga tuff rib
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) Other (explain)
Sealed roof decking explanation for other option. purlins over shingles
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: Use Existing
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
12/9/2024 Application pending.
12/15/2024 Application submitted by applicant.
12/16/2024 Final Review - Documents Required NEED * DAVID J PABST STATE LICENSE & LIABILITY INSURANCE & WORKERS COMP & EMPLOYEES WORKERS COMP EXPIRED. * APPLICANT ADDRESS IS NEEDED.
12/16/2024 Final Review - Corrections Needed NEED * APPLICANT ADDRESS IS NEEDED (CITY, STATE, ZIP) & CORRECT PHONE NUMBER
12/16/2024 Final Review - Payment Needed
12/22/2024 Permit Issued Permit # created and approved from payment.
Contractors
Name/ Business License Title Role
David J Pabst
Whittle Roofing Company, Inc.
CCC1326372 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Anthony Aslan 12/31/2024
Passed: Re-Roof - Final Anthony Aslan 1/22/2025