Permit Details

Permit Search

Permit

New Residential Construction

281 SW SILVER PALM DR
LAKE CITY, FL 32024

Permit #
000051714
Application #
66826
Status Completed
  1. Submitted Aug 27, 2024
  2. Issued Dec 5, 2024
  3. Expires Jun 2, 2026
  4. Completed Dec 4, 2025

Property

Parcel #
02731-090
Owner
Adams Homes Of Northwest Florida, Inc,
Acres
0.24
Subdivision
Preserve At Laurel Lake Unit 1
Zoning
PRD
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
117.30'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0290D
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1647
Total Area (Sqft)
2264
Building Height
20.2
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
x-city
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Point Review - On Hold-Incomplete
  5. Point Review - On Hold-Incomplete
  6. Point Review - Printed-Online Application
  7. Point Review - Reviewed
  8. Zoning Review - Corrections Needed
  9. Zoning Review - Corrections Needed
  10. Point Review - Reviewed
  11. Zoning Review - Reviewed
  12. Plan Review - Building Approved
  13. Plan Review - Electrical Approved
  14. Plan Review - Mechanical Approved
  15. Plan Review - Plumbing Approved
  16. Plan Review - Fuel/Gas Approved
  17. Plan Review - Reviewed
  18. Final Review - Corrections Needed
  19. Final Review - Corrections Needed
  20. Final Review - Corrections Needed
  21. Final Review - Corrections Needed
  22. Final Review - Documents Required
  23. Final Review - Payment Needed
  24. Final Review - Payment Needed
  25. Permit Issued

Contractors

  • William Adams

    Adams Homes Of Northwest Florida Inc

    License
    CRC1330146
    Title
    Cert. Residential
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • Joseph H Strada Jr

    Strada Services Inc Dba Strada Electric & Security

    License
    EC13003715
    Title
    Cert Electrical
    Role
    Subcontractor

    Liability Insurance & Workers Comp Expired.

  • Joseph H Strada Jr

    Strada Services Inc

    License
    CAC043953
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. Jan 17, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  2. Jan 21, 2025

    Passed: Building - Monolithic Slab

    Inspected by Troy Crews

  3. Jan 21, 2025

    Passed: Engineering - Setbacks

    Surveyor To Confirm Setbacks

    Inspected by Troy Crews

  4. Feb 5, 2025

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  5. Feb 5, 2025

    Cancelled: Building - Roof Decking

    Inspected by Troy Crews

  6. Feb 5, 2025

    Cancelled: Building - Strapping

    Inspected by Troy Crews

  7. Feb 5, 2025

    Cancelled: Building - Wall Sheathing

    Inspected by Troy Crews

  8. Feb 6, 2025

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  9. Feb 6, 2025

    Cancelled: Building - Roof Decking

    Inspected by Troy Crews

  10. Feb 6, 2025

    Cancelled: Building - Strapping

    Inspected by Troy Crews

  11. Feb 6, 2025

    Cancelled: Building - Wall Sheathing

    Inspected by Troy Crews

  12. Feb 7, 2025

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  13. Feb 7, 2025

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  14. Feb 7, 2025

    Passed: Building - Strapping

    Inspected by Troy Crews

  15. Feb 7, 2025

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  16. Feb 20, 2025

    Passed: Building - Framing

    Inspected by Troy Crews

  17. Feb 20, 2025

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  18. Feb 20, 2025

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  19. Feb 20, 2025

    Failed: Plumbing/Gas - 2nd Rough-In

    Not Complete

    Inspected by Troy Crews

  20. Feb 20, 2025

    Failed: Plumbing/Gas - Tub Set/Shower Pan

    Not Complete

    Inspected by Troy Crews

  21. Feb 24, 2025

    Passed: Building - Insulation

    Inspected by Troy Crews

  22. Feb 24, 2025

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  23. Feb 24, 2025

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Troy Crews

  24. Mar 25, 2025

    Cancelled: Electrical - Permanent Power

    Inspected by Melissa Garber

  25. Mar 26, 2025

    Failed: Electrical - Permanent Power

    No Grounding Electrode Wire Installed

    Inspected by Troy Crews

  26. Mar 27, 2025

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  27. Mar 27, 2025

    Release to power company

    Driveway Final Required Prior To Release Of Power To Fpl-- Rec'd 3.28.25

    Inspected by Troy Crews

  28. Mar 28, 2025

    Submitted Power Release through FPL Portal

    Inspected by Garber, Melissa

  29. Jun 9, 2025

    Passed: City of Lake City Utilities - Lake City Utilities Tap Inspection

    Inspected by City Of Lake City Distribution And Collections Department

  30. Dec 4, 2025

    Passed: Building - Final

    All Requirements Met To Release Co-- 12.4.25 Mg

    Inspected by Troy Crews

Documents